background image

 

 

   

 

   

 

   

 

CERTIFICATION 

 

 

Electrical Safety   

EN 62368-1:2020+A11:2020 

   

 

Emissions   

EN 55032:2015+A1:2020 

Radiated Immunity   

EN 55035:2017+A1:2020 

Harmonic Emissions   

EN 61000-3-2:2014 

Fluctuations and Flicker   

EN 61000-3-3:2013 

Electro-Static Discharge   

EN 61000-4-2:2009 

Electromagnetic Field Immunity   

EN 61000-4-3:2010 

Electrical Fast-Transients   

EN 61000-4-4:2012 

Surge   

EN 61000-4-5:2014+A1:2017 

Conducted Immunity   

EN 61000-4-6:2014 

   

 

RoHS   

IEC 63000:2018 

 

 

 

For all technical enquiries regarding this product, please contact our technical support team using the 
following email address: 

 

[email protected]

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for PDT-NSU-7216-PA-SF-R

Page 1: ...Operations Manual PDT NSU 7216 PA SF R Revision 1 0 April 2022...

Page 2: ...5 1 AI VLAN Mode 6 5 2 AI Extend Mode 6 5 3 AI Power Supply Mode 6 5 4 AI QoS Mode 6 6 Connectors and Configuration Options 7 6 1 LED Indicators 7 6 2 Mode Selection Switches 7 6 3 SFP Ports 8 6 4 RJ4...

Page 3: ...1 Revision History Date Rev By Comments Checked Date 20 04 2022 01 JF Initial Release SC 22 04 2022...

Page 4: ...elligence AP Access Point IEEE Institute of Electrical and Electronic Engineers IP Internet Protocol MTBF Mean Time Between Failures PD Power Device PoE Power over Ethernet PSU Power Supply Unit QoS Q...

Page 5: ...The Unit should be mains fed using the supplied AC Power Lead which is fitted with a 3A Fuse If the device is to be fed from an alternative power source then the appropriate circuit protection device...

Page 6: ...t Passive PoE Switch 1 x Rackmount Kit 1 x Mains AC Power Lead Operation Maintenance Manual Declaration of Conformity 5 Product Overview The PDT NSU 7216 PA SF R is an Unmanaged Gigabit AI Passive PoE...

Page 7: ...able where the power source is too far away for conventional configurations but the bandwidth limitation should not be overlooked when incorporating this feature into network designs 5 3 AI Power Supp...

Page 8: ...Tx Rx SPD Port Data Rate Green OFF 10 100 Mbps ON 1000 Mbps 6 2 Mode Selection Switches The Mode Selection Switches toggle AI functionality modes as follows AI VLAN Mode Isolates Ports 1 16 from each...

Page 9: ...onnectivity to a range of suitable peripherals PoE Power is provided on the RJ45 pins as follows Pins Type 4 5 24VDC 7 8 GND Rear Panel 6 5 GND Terminal The Unit incorporates an external GND terminal...

Page 10: ...n below Once the brackets are securely fitted the unit should be positioned so that the mounting holes in the brackets are aligned to the rack holes The unit should then be secured using captive fixin...

Page 11: ...e carrying pins continuously and users should check that all PoE powered devices to be used are compatible with 24VDC supply voltage 8 3 SFP Connections The SFP Ports incorporated into this unit only...

Page 12: ...47 616Mbps INTERFACE Wired 16 x RJ45 Optical 2 x SFP 1000 BASE X or 100 BASE FX PoE Standard IEEE 802 3af Mode B Port RJ45 Power Pin Assignment 4 5 7 8 PoE output 24VDC PoE Budget 300W Max ENVIRONMENT...

Page 13: ...000 3 3 2013 Electro Static Discharge EN 61000 4 2 2009 Electromagnetic Field Immunity EN 61000 4 3 2010 Electrical Fast Transients EN 61000 4 4 2012 Surge EN 61000 4 5 2014 A1 2017 Conducted Immunity...

Reviews: