5: BASIC Stamp Command Reference – PAUSE
BASIC Stamp Programming Manual 2.0c
•
www.parallaxinc.com
•
Page 213
PAUSE
BS1 BS2 BS2e BS2sx BS2p
PAUSE
Period
Function
Pause the program (do nothing) for the specified Period.
•
Period
is a variable/constant/expression (0 – 65535) that specifies
the duration of the pause. The unit of time for Period is 1
millisecond.
Explanation
PAUSE delays the execution of the next program instruction for the
specified number of milliseconds. For example:
Flash:
LOW 0
PAUSE 100
HIGH 0
PAUSE 100
GOTO Flash
This code causes pin 0 to go low for 100 ms, then high for 100 ms. The
delays produced by PAUSE are as accurate as the ceramic-resonator time
base (on the BASIC Stamp modules), ±1 percent. When you use PAUSE in
timing-critical applications, keep in mind the relatively low speed of the
PBASIC interpreter. This is the time required for the BASIC Stamp to read
and interpret an instruction stored in the EEPROM.
Demo Program (PAUSE.bs2)
' This program demonstrates the PAUSE command's time delays. Once a second, the
' program will put the message, "paused" on the screen.
'{$STAMP BS2} 'STAMP directive (specifies a BS2)
Again:
DEBUG "paused", cr
PAUSE 1000
GOTO Again
1
2
e
2
sx
2
p
2
1
1
NOTE: Expressions are not
allowed as arguments on the BS1.
2
e
2
sx
2
p
2
NOTE: This is written for the BS2
but can be used for the BS1, BS2e,
BS2sx and BS2p also. Locate the
proper source code file or modify
the STAMP directive before
downloading to the BS1, BS2e,
BS2sx or BS2p.
Summary of Contents for BASIC Stamp 1
Page 1: ...BASIC Stamp Programming Manual Version 2 0c...
Page 34: ...Quick Start Guide Page 32 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Page 340: ...ASCII Chart Page 338 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Page 342: ...Reserved Words Page 340 BASIC Stamp Programming Manual 2 0b www parallaxinc com...
Page 346: ...Conversion Formatters Page 344 BASIC Stamp Programming Manual 2 0b www parallaxinc com...