9

Copyright 2020 © Paragon Tank Truck Equipment

Oil Capacity

Horizontal Airflow 
(Standard Mount)

Vertical 

Airflow

Drive End 
Non-Drive End

28.32 oz.  
38.57 oz. 

35.18 oz.  
46.73 oz.

Preventative Maintenance 

• 

Inspect blower mounting, driveline, PTO and air filter for integrity. 

Verify melt plugs are intact - replace as needed prior to operation. 

• 

Remove camlock dust cap and connect the hot air hose. 

• 

Follow trailer manufacturers recommendation regarding product hose connection and valve operation. 

• 

Slowly engage PTO with engine at idle. 

• 

Bring up to operating speed and lock engine at recommended speed (shown in cab). 

• 

Unload trailer as per trailer manufacturer’s recommendation and 

do not exceed 

maximum tank pressure.   

• 

While discharging, visually check blower for vibration, mechanical noise or excessive heat. 

• 

If relief valve is operating adjust proportioning valve to reduce tank pressure. 

• 

Reduce pressure to zero as per trailer manufacturers instructions. 

• 

Disengage PTO (No cool down period required). 

• 

Disconnect blower hose and replace camlock dust cap. 

Caution: 
 

- The blower and accessories will become hot enough to cause serious skin burns on contact. 

 - Rotating machinery is dangerous. 
- Always wear ear protection when in close proximity to blower. 

 

           

Horizontal 

Airflow

Filler Plug

Sight Glass 

(5/8 Full)

Magnetic 

Drain Plug

Filler Plug

Sight Glass  

(5/8 full)

Magnetic 

Drain Plug

Standard  Oil: P858/P1057 oil  (Paragon part number: 409-002) 

Caution: Mixing or incorrect oil can result in gear and  

 

bearing failure.

Daily

Weekly

Monthly

Semi-Annually

1.Check and maintain oil 

level, add oil as 

necessary.

1.Clean Air Filter.  Clogged air filters can 

seriously affect the efficiency of the blower.

1.Inspect the entire 

system for leaks.

1.Inspect the driveline 

components.

1.Check Air Filter element.

2.Check Relief Valve to assure it is operating 

properly.

2.Inspect condition of oil 

and change if necessary.

2.Change oil (even if 500 

operating hours has not 

been reached).

 

A good maintenance program will keep your P858/P1057 blower in top running condition.  A newly installed P858/

P1057 blower should be checked frequently during the first month of operation, especially lubrication.  Check oil levels 
and add as needed.  Complete oil changes are recommended 

every 500 operating hours

, or more frequently (An oil 

analysis program is recommended).  Below is Paragon’s recommended minimum maintenance program.

Blower Operation 

Lubrication Instructions 

Correct Level 

Over filled 

Under Filled

Sight Glass 

Filling 

Instructions

Vertical 

Airflow

Summary of Contents for P858

Page 1: ...Installation and Operation Manual Truck Blower P858 P1057 Operation Manual Version 02 17 2022 ...

Page 2: ...ormation 3 Blower Specifications 4 Mounting 5 7 Power Take Off 5 Mounting Bracket Requirements 5 Determine Blower Mounting Slope 5 Suction Equipment 5 Delivery Discharge Pipework 5 Drive Shaft Installation 5 6 Blower Orientation 7 Preventative Maintenance 8 Lubrication Instructions 8 Blower Operation 8 Parts Listings 9 14 Warranty Information 15 Safety Notice ...

Page 3: ...k ____________________________ Transmission ____________________________ PTO ____________________________ PTO Ratio ____________________________ Blower model ____________________________ Blower serial ____________________________ Date ____________________________ Inspected by ____________________________ Is PTO ratio torque and rotation correct Mount PTO as per manufacturer s recommendations and r...

Page 4: ...si at 1800 RPM Audible sound from the plug alerts the driver of a problem Operator should shut down blower and try to locate the problem When the problem is corrected operator can fit a new plug left hand thread or use the plug from the suction side of the machine Note Replace blown melt plugs immediately to prevent further damage to the blower Do not re install blown melt plugs Fig 1 Caution If p...

Page 5: ...ure Performance and Horsepower Vacuum Performance and Horsepower 12 PSIG 16 PSIG 18 PSIG 20 PSIG 12 of Hg 16 of Hg 17 of Hg CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP CFM BHP 1800 479 33 462 42 447 50 437 55 493 17 464 21 440 23 29 1900 514 35 497 44 482 52 472 58 528 18 498 22 475 24 59 2000 549 37 532 46 516 55 507 61 563 18 533 23 510 25 88 2100 584 39 566 49 551 58 541 64 597 19 568 24 54...

Page 6: ...31 1900 679 47 648 62 635 70 628 73 697 23 657 29 626 32 2000 725 49 694 65 681 73 674 77 743 24 703 30 572 35 2100 771 52 740 69 727 77 720 81 789 25 749 32 718 36 2200 817 54 786 72 773 81 766 85 835 27 795 33 764 38 2300 863 57 832 75 819 84 812 89 881 28 841 35 810 39 2400 909 59 878 79 865 88 858 93 927 29 887 36 856 41 2500 955 61 924 82 911 92 904 97 973 30 933 38 902 43 2600 1001 65 970 85...

Page 7: ...her non moveable object to prevent damage to the blower Check Valve Sized for maximum CFM with minimal restriction Should have at least 1 check valve mounted on the trailer at the hot air hose connection Must be inspected periodically for damage Mufflers Sized for maximum CFM with minimal restriction Mounted downstream of the relief valve Stainless steel is required for sensitive product applicati...

Page 8: ...69 7 Copyright 2020 Paragon Tank Truck Equipment 1310 Drive Flange 1 5 8 w 3 8 key Part Number 560 044 Drive Shaft to be field supplied Companion yoke reference industry part number 2 2 329 not provided by Paragon ...

Page 9: ...her Out In Magnetic Drain Plug Sight Glass Breather Out In Magnetic Drain Plug Sight Glass Breather Vertical Airflow VA 1 2 VA Driver Side VA Passenger Side Sight Glass Breather Magnetic Drain Plug In Out Sight Glass Breather Magnetic Drain Plug In Out NOTE Sight glasses and magnetic drain plugs will need to be re positioned prior to installation and or filling with oil All models are shipped in t...

Page 10: ...ating machinery is dangerous Always wear ear protection when in close proximity to blower Horizontal Airflow Filler Plug Sight Glass 5 8 Full Magnetic Drain Plug Filler Plug Sight Glass 5 8 full Magnetic Drain Plug Standard Oil P858 P1057 oil Paragon part number 409 002 Caution Mixing or incorrect oil can result in gear and bearing failure Daily Weekly Monthly Semi Annually 1 Check and maintain oi...

Page 11: ...charge Flange 1 15 526 002 Flange Gasket 1 16 128 025 M12 x 30 Bolt Discharge Flange 4 17 196 008 M12 Washer Discharge Flange 4 18 128 037 Cap Screw M16 x 35mm 4 19 194 007 M16 Lock Washer 4 20 228 095 5 8 Cap Screw Angle Strap 2 21 294 011 5 8 Lock Washer Angle Strap 2 22 296 014 5 8 Flat Washer Angle Strap 2 23 284 015 5 8 Nut Angle Strap 2 24 601 017 P858 Blower 1 24 601 016 P1057 Blower 1 25 5...

Page 12: ...Suction AI 1 43 588 002 Suction Pipe Al 20 1 44 90525 2 Bevel Washer 1 2 2 Horizontal Airflow HA Diagram P N Description QTY 1 625 006 Filter Assy S S P858 P1057 psi only 1 2 625 002 Filter Assy S S P858 P1057 psi vac 1 5 533 005 2 Street Elbow 1 6 610 012 Relief Valve 16 psi 1 6 610 013 Relief Valve 18 psi 1 7 565 001 Dustcap 3 1 7 565 002 Dustcap 4 1 8 567 002 Camlock 3 male x 4 NPTM 1 8 533 045...

Page 13: ...crew Skt Hd M12 X 55mm 2 33 124 025 Capscrew Skt Hd M12 X 110mm 2 P N Description QTY 34 587 005 Hose 3 1 2 long x 5 ID EPDM 1 35 508 058 Bracket Mounting Paragon Air Filters 1 36 563 000 Muffler 4 MNPT x 4 FNPT Steel 1 36 563 001 Muffler 4 MNPT x 4 FNPT S S 1 37 228 065 1 2 Bolt Discharge Flange 4 38 294 010 1 2 Washer Discharge Flange 4 39 509 001 Flange Delivery CI H A 1 40 508 061 Mounting Bra...

Page 14: ...8 P1057 CDL9 CDL12 Not Shown 1 J 526 000 Gasket 1 O 184 004 SS hex body for Filter Band Clamp 1 Item P N Description Qty A 576 009 Cap Assembly PSI VAC 1 B 576 012 Rubber Flex Latch 2 C 576 010 Head Assembly P858 P1057 Latches 1 D 612 043 Kit Bracket set of 2 S S Air Filter Mounting 1 G 533 045 Camlock 4 male 1 H 576 008 Clamp Assembly Includes Wingnut Item O 1 J 526 000 Gasket 1 K 575 007 Filter ...

Page 15: ... 800 471 8769 14 Copyright 2020 Paragon Tank Truck Equipment ...

Page 16: ... Rotor 2 18 502 008 P1057 Blower Rotor 2 19 298 010 Key 3 8 x 3 8 x 1 5 8 1 1 20 571 028 Spacer Wear Sleeve 2 2 21 558 003 Seal Gamma Rotary 2 2 22 124 022 Capscrew ISO M12 28 28 22 124 030 Capscrew LP M12 4 4 23 323 005 Hyd Plug 4 4 24 543 003 Melt Plug 3 3 25 500 040 P858 Blower Body 1 25 500 039 P1057 Blower Body 1 26 501 013 Blower Sideplate NDE 1 1 27 141 001 Magnetic Drain Plug 2 2 28 523 04...

Page 17: ... 800 471 8769 16 Copyright 2020 Paragon Tank Truck Equipment Additional Notes ...

Page 18: ...ove and its approval Seller shall either repair or replace its product part or work at the original Ex works point of shipment or refund an equitable portion of the purchase price The products and parts sold hereunder are not warranted for operation with erosive or corrosive materials or those which may lead to build up of materials within the product supplied nor those which are incompatible with...

Reviews: