CAUTION: 

It is the installer’s responsibility to ensure that the HydraFLOW is mounted in a location 

  providing proper clearance from any heat source(s). 

                       Paragon recommends 12” from any exhaust opening, 6” from any other heat source(s).

 

 

Installation

Power Take-Off and Hydraulic Pump 

A. Mount the PTO as recommended by PTO manufacturer. 

B. If the system contains a direct mounted hydraulic pump, ensure the hydraulic pump is mounted to the PTO as 

recommended by PTO, hydraulic pump, and transmission manufacturers. 

C. Ensure ALL safety labels are installed per manufacturer guidelines. 

Note: The standard filter supplied in the HydraFLOW is a 10 micron nominal. Contact Paragon Tank Truck Equipment for other filtration 
media options. 

Please refer to your hydraulic pump installation manual for correct filtration and suction specifications. 

Contact the engine manufacturer for the proper engine speed range that will reduce torsional vibration to a minimum and prevent 
premature hydraulic pump and PTO wear.

Mounting the HydraFLOW 

• Drill 21/32” diameter holes in the appropriate location for mounting the unit as shown in 

Fig. 4

• Use the fasteners in the hardware packet supplied by Paragon to mount the 

HydraFLOW. 

Suction Hose Chart

GPM Flow

Hose Size

0-20

1-1/4”

20-25

1-1/2”

26-50

2”

Hydraulic Hoses & Fittings 

DO NOT 

use thread tape or pipe dope on threaded connections, this will contaminate the hydraulic system. 

ALL

 HD model coolers have a 2” female National Pipe Thread connection located on the bottom of the cooler. 

ALL

 hydraulic hoses must be supported and not allowed to hang on the cooler connections. 

• Use of Loctite 542 or equivalent is recommended for any National Pipe Thread (NPT) hydraulic connections. 

• Hoses are customer supplied, fit according to the system drawings. 
• High pressure hoses must have a pressure rating equal to or higher than the hydraulic system relief valve setting. 
• The suction hose must be capable of operating in 28” Hg vacuum service. 

Fig. 1

Summary of Contents for HydraFLOW

Page 1: ...Operator s Manual November 04 2019 Copyright Paragon Tank Truck Equipment LLC INSTALLATION OPERATION AND MAINTENANCE MANUAL WARNING DO NOT OPERATE MACHINERY BEFORE READING MANUAL FULLY 50 gpm max 300...

Page 2: ...e reviewed by ALL operators Safety instruction tags were attached to your unit prior to shipment DO NOT remove paint over or obscure in any manner Failure to heed these warnings could result in seriou...

Page 3: ...Parts List 8 12 Warranty 13 CONGRATULATIONS on your purchase of a new HydraFlow Please examine the unit for shipping damage and if any damage is found report it immediately to the carrier If unit is...

Page 4: ...stalled Install a support strap when servicing a drive shaft to prevent personal injury Always use hose rated for hydraulic duty and at the correct pressure A serious or fatal injury can occur if you...

Page 5: ...engine speed range that will reduce torsional vibration to a minimum and prevent premature hydraulic pump and PTO wear Mounting the HydraFLOW Drill 21 32 diameter holes in the appropriate location for...

Page 6: ...ow 3 4 High Pressure to Hydraulic Motor 3 4 Low Pressure Return Motor to HydraFlow 1 Alternate Frame Rail Mount Fig 3 Note Review Hose Chart Fig 1 to ensure the correct suction hose sizing For off roa...

Page 7: ...e oil level Initial Start Up Two People Required Maintenance Daily Check oil level before operating the system must be off Correct oil level is the bottom sight glass completely full and the top sight...

Page 8: ...02 16 Tee HP 16 Elbow LP 300 3000 psi 004 16 Elbow HP 20 Tee LP Style Features T Tank X No Guard Suction Connection 2 2 NPT Suction connection 2 NPT Female HP connections 1 JIC Males in out Return con...

Page 9: ...1 006 Filter Assy w Spring 351 003 Filter Lid 522 001 Hold Down Spring 580 001 Filter Element 350 000 Included with Di user Assy Included with Filter Assy Spring is optional Filter Lid Assy Hold Down...

Page 10: ...9 Filter Head Options Filter Head without Lip Part 352 005 Filter Head with Lip Part 352 009...

Page 11: ...10 Parts List...

Page 12: ...12NPTM 1 1 16 335 002 Radiator Byspass Valve 1 1 17 85227 Barb to check valve 3 4 hose barb x 3 4 NPTM 1 1 18 322 027 Flow Control for 300 007 1 1 19 322 026 Fan Motor Flow Control Valve for 300 001...

Page 13: ...er Foot 43 85236 Hose fan motor return 1 2 per foot Per Foot Per Foot 44 360 001 Hose rad out 1 per foot 1 1 45 360 000 Hose rad in 1 per foot 1 1 46 361 000 Hose fan motor feed 1 1 47 313 017 Hose Cl...

Page 14: ...WARRANTIES OF MERCHANTABILITY AND FITNESS OF PURPOSE After Buyer s submission of a claim as provided above and its approval Seller shall at its option either repair or replace its product part or wor...

Reviews: