34
LT5052 (ISS 5)
SECTION ELEVEN Maintenance Instructions (maintenance instructions)
GENERAL
Servicing should be carried out annually by a competent person such as a CORGI-registered person in accordance
with the relevant regulations, to ensure the safe and correct operation of the appliance.
Warning:
Before commencing any service or replacement of parts, isolate the appliance from the electrical
supply and turn off the gas supply to the fire.
After servicing check for gas soundness and reconnect the electricity supply.
When ordering spare parts please quote appliance name and serial number, these can be found on the data
badge, which is located behind the decorative trim.
Important:- Refer to Health & Safety Notice(Page 5)at the front of this booklet before removing the fuel
bed components.
Examine the fuel bed for signs of cracking and replace if necessary.
IMPORTANT
Section Four: Fuel Bed Cleaning & Layout before attempting to replace fuel bed components, which should only be
replaced as a complete set with no extra components added.
PILOT LINTING
Check pilot aeration holes for linting, use a vacuum cleaner nozzle taking care not to damage the pilot head
REPLACEMENT OF GAS CONTROL
1.
Turn off the gas supply and isolate the appliance from the electricity supply.
2.
Remove fire fret.
3.
Remove all fuel bed components.
4.
Remove the 4 screws from the fascia plate.
5.
Isolate and disconnect fire at inlet elbow
6.
Remove the 2 screws from the top of burner support and remove fire from the casing
7.
Carefully remove the two wires from the interrupter at rear of gas valve
8.
Disconnect thermocouple from the interrupter at rear of gas valve
9.
Pull off control knob and disconnect all 3-gas connections to gas valve
10.
Remove 2 screws securing valve to fire, repair or replace as necessary.
11.
Re-assemble the in reverse order.
12.
Turn on the gas supply and check for soundness.
13.
Restore electrical supply and recommission appliance.