Paradyne TNE1520-P Installation Instructions Manual Download Page 12

12

LED Indicators

This document describes units manufactured after 13 January 2005. See the prior 
version of this document for information about units manufactured on or before that date.

Whenever both T1 connections lose link or experience a T1 Alarm, the Ethernet link is 
automatically be disabled (as indicated by no illumination of the Ethernet 100, Act and 
Lnk LEDs). Upon reestablishment of at least one of the T1 connections, the Ethernet 
link is reinstated and the Ethernet LEDs reflect current Ethernet Status.  

Table 10.  LEDs (1 of 2)

LED

STATE

INDICATION

ADDITIONAL 
INFORMATION

T1 
Connections 
Lnk (Port 1 
and Port 2)

Flashing* 
Green

T1 connection is 
established and active

Traffic is flowing.

Solid Green Problematic T1 connection

A connection exists but 
there is indication of a 
problem with the T1 line.

No 
Illumination

Red Alarm: The incoming 
connection to the unit has 
been lost; no data is being 
received.

If the outgoing connection 
from the unit has also been 
lost then the unit's partner 
TNE1520 will be in Red 
Alarm as well.

T1 
Connections 
Alm (Port 1 
and Port 2)

No 
Illumination

T1 is operational

An established T1 link has 
no alarm indications and is 
operational unless the T1 
Lnk LED remains unlit as 
well, in which case the 
TNE1520 is in Red Alarm.

Solid 
Amber

Yellow Alarm: The outgoing 
connection from the unit 
has been lost; no data is 
being transmitted.

The unit's partner 
TNE1520 has lost its 
incoming connection and is 
in Red Alarm.

Pulsing* 
Amber

Blue Alarm: An indirect 
connection has been lost; 
the unit may no longer be 
receiving data from its 
partner TNE1520.

The unit's partner 
TNE1520 has lost a 
connection with an 
intermediate device and is 
in Red or Yellow Alarm.

Power

Solid Green TNE1520 is operational

If the Power LED is not 
illuminated, it is unlikely 
that the TNE1520 is 
receiving power and 
therefore none of the LEDs 
will be illuminated.

Summary of Contents for TNE1520-P

Page 1: ...one Network 16 Important Safety Instructions 17 Software and Firmware License Agreement ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS YOU MAY USE THE SOFTWARE AND OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE AGREEMENT IN THE EVENT THAT YOU DO NOT AGREE WITH ANY OF THE TERMS OF THIS LICENSE ...

Page 2: ...e shall not copy the Software except for a single archival copy 5 Except for the Product warranty contained in the manual the Software is provided AS IS and in its present state and condition and Paradyne makes no other warranty whatsoever with respect to the Product purchased by you THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED OR ORAL OR WRITTEN INCLUDING WITH...

Page 3: ...ntation for Paradyne products is available at www paradyne com Select Support Technical Manuals To order a paper copy of a Paradyne document or to speak with a sales representative please call 1 727 530 2000 Warranty Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning...

Page 4: ...he Ethernet link will remain disabled as indicated by no illumination of the Ethernet 100 Act and Lnk LEDs until at least one of the two T1 connections has been established 04 17608 Port 2 T1 Connection Power Lnk 100 Act Lnk 10 100 Ethernet Connection T1 Network Extender TNE1520 Port 1 Alm 10 100 Connection Port 1 Port 1 Config 04 17581 Power Adapter 5V DC Port 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Po...

Page 5: ... USED Port 2 timing is determined by the Port 1 timing 8 NOT USED NOT USED Table 2 TNE1520 S Subscriber Configuration Switches Switch Port 1 Port 2 1 NOT USED The TNE1520 S determines speed via communication with its partner T1 provider unit NOT USED The TNE1520 S determines speed via communication with its partner T1 provider unit 2 3 Frame Type NOT USED Port 2 frame type is determined by the Por...

Page 6: ...unication with its partner T1 provider unit Frame Type Port 1 Only Switch 3 Frame type is the T1 data encapsulation method A frame consists of 193 bits 8 bit samples of each of the 24 T1 data channels plus a synchronization bit transmitted at a rate of 8 000 frames per second 1 536 kbps across the T1 line Extended Super Frame Extended Super Frame ESF format used in Wide Area Networks WANs assemble...

Page 7: ...nes density requirement in the North American public network B8ZS line encoding helps prevent loss of synchronization between the TNE1520 and remote T1 equipment by using bipolar violations to guarantee the presence of pulses in the T1 line Alternate Mark Inversion Alternate Mark Inversion AMI alternates positive and negative pulses Port 1 Configuration Switch 4 on the TNE1520 P and the TNE1520 S ...

Page 8: ...ingly Port 1 Configuration Switches 5 and 6 on the TNE1520 control the line attenuation of both T1 links Port 1 and Port 2 line attenuation for the two links cannot be configured independently Timing Port 1 Only Switch 7 TNE1520 P Only Timing refers to the clock source for T1 transmission links Local Local clock source refers to timing derived from an oscillator onboard the TNE1520 P Loop Loop clo...

Page 9: ...mportant 2 Verify both connections the Port 1 and Port 2 Lnk LEDs on the front of the TNE1520 will pulse green to indicate the connections are established and operational Single T1 Connection A single line connection can be established between a TNE1520 P and any of Paradyne s T1 subscriber units regardless of loop bonding capability Likewise a single line connection can also be established betwee...

Page 10: ...the back of the TNE1520 Verify the connection solid green illumination of the 10 100 Ethernet Connection Lnk Link LED on the front of the TNE1520 indicates a connection has been established If the Ethernet Lnk LED is illuminated but not the Ethernet 100 LED then a 10 Mbps connection has been established If the Ethernet Lnk AND 100 LEDs are both illuminated then a 100 Mbps connection has been estab...

Page 11: ...11 Table 9 Ethernet Pinouts Pin Function Pin 1 Rx Pin 2 Rx Pin 3 Tx Pin 4 not used Pin 5 not used Pin 6 Tx Pin 7 not used Pin 8 not used ...

Page 12: ...rm The incoming connection to the unit has been lost no data is being received If the outgoing connection from the unit has also been lost then the unit s partner TNE1520 will be in Red Alarm as well T1 Connections Alm Port 1 and Port 2 No Illumination T1 is operational An established T1 link has no alarm indications and is operational unless the T1 Lnk LED remains unlit as well in which case the ...

Page 13: ...lid Amber Heavy traffic No Illumination N Either there is no Ethernet link or a link exists but there is no activity 10 100 Ethernet Connection Lnk Solid Green Ethernet connection is established If the Ethernet Lnk LED is illuminated but not the Ethernet 100 LED then a 10 Mbps connection has been established If the Ethernet 100 LED is also illuminated then a 100 Mbps connection has been establishe...

Page 14: ...s A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada ACTA Customer Information This equipment complies with Part 68 of the FCC rules and the requirements adopted by the Administrative Council for Terminal Attachments ACTA On the bottom of the network extender is a label that contains among other information a product ...

Page 15: ...errupted service If trouble is experienced with this equipment please contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods Internet Visit the Parady...

Page 16: ...enior Vice President Chief Financial Officer Notice to Users of the Canadian Telephone Network NOTICE This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications This is confirmed by the registration number The abbreviation IC before the registration number signifies that registration was performed based on a Declaration of Conformity indicating that Industry Ca...

Page 17: ...e phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 8 Input powe...

Page 18: ...18 ...

Page 19: ...19 ...

Page 20: ...20 TNE1 A2 GN12 20 TNE1 A2 GN12 20 ...

Reviews: