Paradyne SNE2020G-P Installation Instructions Manual Download Page 15

15

Notice to Users of the Canadian Telephone Network

NOTICE: This equipment meets the applicable Industry Canada Terminal Equipment 
Technical Specifications. This is confirmed by the registration number. The abbreviation 
IC before the registration number signifies that registration was performed based on a 
Declaration of Conformity indicating that Industry Canada technical specifications were 
met. It does not imply that Industry Canada approved the equipment.

NOTICE: The Ringer Equivalence Number (REN) for this terminal equipment is labeled 
on the equipment. The REN assigned to each terminal equipment provides an indication 
of the maximum number of terminals allowed to be connected to a telephone interface. 
The termination on an interface may consist of any combination of devices subject only 
to the requirement that the sum of the Ringer Equivalence Numbers of all the devices 
does not exceed five. 

If your equipment is in need of repair, contact your local sales representative, service 
representative, or distributor directly.

CE Marking

When the product is marked with the CE mark on the equipment label, a supporting 
Declaration of Conformity may be downloaded from the Paradyne World Wide Web site 
at 

www.paradyne.com

. Select 

Library 

 Technical Manuals 

 

CE Declarations of 

Conformity

.

Japan Notice

Class A ITE

This is a Class A product based on the standard of the Voluntary Control Council for 
interference by Information Technology Equipment (VCCI). If this equipment is used in a 
domestic environment, radio disturbance may arise. When such trouble occurs, the user 
may be required to take corrective actions.

Important Safety Instructions

1.

Read and follow all warning notices and instructions marked on the product or 
included in the manual.

2.

Do not allow anything to rest on the power cord and do not locate the product where 
persons will walk on the power cord.

!

Summary of Contents for SNE2020G-P

Page 1: ...ion Online 3 Introduction 4 Package Contents 4 Connecting to Power 5 Switchpack Configuration 6 Connecting the SHDSL Lines 8 Connecting the Ethernet Line 10 Ferrite Chokes 10 LED Indicators 11 EMI Notices 13 ACTA Customer Information 13 Supplier s Declaration of Conformity 14 Notice to Users of the Canadian Telephone Network 15 CE Marking 15 Japan Notice 15 Important Safety Instructions 15 ...

Page 2: ... notice to Paradyne and an agreement in writing to additional terms 3 The Licensee shall not reverse engineer decompile or disassemble the Software in whole or in part 4 The Licensee shall not copy the Software except for a single archival copy 5 Except for the Product warranty contained in the manual the Software is provided AS IS and in its present state and condition and Paradyne makes no other...

Page 3: ...PARADYNE HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES OR FOR ANY CLAIM BY ANY THIRD PARTY 7 The rights granted under this Agreement may not be assigned sublicensed or otherwise transferred by the Licensee to any third party without the prior written consent of Paradyne 8 This Agreement and the license granted under this Agreement shall be terminated in the event of breach by the Licensee of...

Page 4: ...oduct two copper pairs may be used to deliver double the bandwidth at any given distance In addition the SNE2020 can be used in a point to point deployment for high speed copper connections between two locations Loop bonded SHDSL provides automatic load balancing and fail over to provide optimum redundancy and data throughput all delivered with a plug and play ease of use Package Contents HANDLING...

Page 5: ...d Upon start up the Ethernet link will remain disabled as indicated by solid illumination of the Ethernet Rx Tx and Lnk LEDs until at least one of the two SHDSL connections has been established 1 2 3 4 Ethernet Connection SDSL 2 Power Adapter 5V DC SDSL 1 Configuration SDSL 1 SDSL Connection Power SDSL Connection SDSL 2 Collision Rx Tx Lnk Ethernet Connection SDSL Network Extender 2000 SNE2020 04 ...

Page 6: ...y may be affected Adaptive mode allows the SNE2020G P to train up to the best possible speed supported by the SNE2020G P the remote modem to which it is connected and the copper cable pair s connecting the two The maximum reachable distance for a single line SNE2020G P connection in Adaptive mode is 25 400 feet at 144 kbps Bandwidth cannot be configured on the SNE2020G S Subscriber units determine...

Page 7: ...ection at a time Packet collisions are not unusual Full Duplex Ethernet The Ethernet line can receive and transmit simultaneously effectively increasing aggregate bandwidth from 10 Mbps to 20 Mbps and preventing packet collisions CAUTION If you set the SNE Provider or Subscriber unit to Full Duplex you must also set your connected Ethernet device to 10 Mb Full Duplex Do not connect a Full Duplex E...

Page 8: ...tablish a loop bonding connection 1 Plug your SHDSL cables into the SHDSL RJ45 ports SDSL 1 and SDSL 2 on the back of the SNE2020G The order of connection is not important 2 Verify both connections the SDSL 1 and SDSL 2 LEDs on the front of the SNE2020G will pulse green to indicate the connections are established and operational Single Line Connection Procedure To establish a single line connectio...

Page 9: ...9 Table 3 SDSL RJ45 Port Pin Connection 1 not used 2 not used 3 not used 4 Ring 5 Tip 6 not used 7 not used 8 not used RJ45 Port Cable and RJ45 Connector ...

Page 10: ... Tx and Lnk LEDs until at least one of the two SHDSL links has been established The SNE2020G connects to a PC using a straight through Ethernet cable and to a hub or a switch using a crossover Ethernet cable For any other type of connection the circuit presented by the Ethernet device you are connecting to determines the type of cable you need Ferrite Chokes If ferrite chokes are included with you...

Page 11: ...ination No SHDSL connection If both SHDSL connections are lost the Ethernet LEDs will have these states Collision Off Rx and Tx Solid Amber Lnk Solid Green Ethernet Collision No Illumination Standard Either there is no traffic or traffic is flowing without any collisions If there is no Ethernet connection the Ethernet Collision LED will remain unlit by default An SNE2020G in Full Duplex mode does ...

Page 12: ...id amber Ethernet Rx LED can also signify a lost SHDSL connection No Illumination No activity Either there is no Ethernet link or a link exists but there is no activity Ethernet Tx Flashing Amber Ethernet activity The SNE2020G is transmitting data across the Ethernet network Solid Amber Heavy Tx traffic The SNE2020G is transmitting large amounts of data across the Ethernet network A solid amber Et...

Page 13: ...CES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada ACTA Customer Information This equipment complies with Part 68 of the FCC rules and the requirements adopted by the ACTA On the bottom of the network extender is a label that contains among other information a product identifier in the format US AAAEQ TXXXX If requested this number must be provided to the telep...

Page 14: ...tion to party line service is subject to state tariffs Contact the state public utility commission public service commission or corporation commission for information Supplier s Declaration of Conformity Place of Issue Paradyne Corporation 8545 126th Avenue North Largo FL 33773 1502 USA Date of Issue 7 14 2005 Paradyne Corporation located at the above address hereby certifies that the Model SNE202...

Page 15: ... the Ringer Equivalence Numbers of all the devices does not exceed five If your equipment is in need of repair contact your local sales representative service representative or distributor directly CE Marking When the product is marked with the CE mark on the equipment label a supporting Declaration of Conformity may be downloaded from the Paradyne World Wide Web site at www paradyne com Select Li...

Page 16: ...consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with a Class 2 or Limited Power Source LPS output for use in North America or 2 a certified power source with a Safety Extra Low Voltage SELV o...

Reviews: