3. Configuration
8335-A2-GB20-70
February 2003
3-31
4. Save the changes as prompted.
For . . .
Enter . . .
Seg Endpt (Model
8355 only)
Enable or Disable to determine if the card will function as an
endpoint for ATM Operations, Adminstration and
Maintenance (OAM) loopbacks on the connection.
Enable
– To define the card as a segment loopback on this
connection. The line card will then check the location ID in a
loopback cell and loop the cell if the location ID is valid. If it
is not valid (the location ID does not match the
preconfigured ID or an all-ones ID), the cell will be dropped
(Default = Enable).
Disable
– To loop a cell only if the location ID matches the
preconfigured location ID. All other loopback cells are
passed to the next segment.
CSN
The Connection Serial Number (CSN) is an automatically
generated identifier for this connection that associates it
with a connection on the SCM card. It consists of the
following:
Slot Number (
01–18
for the 8820 GranDSLAM,
01–03
for the 8620 GranDSLAM)
Connection Type (
S
for Standard or
C
for Custom)
Port Number (
01–16
on the Model 8335,
01–12
on the
Model 8365, or
01–24
on the Model 8355 or 8385)
A system-assigned 3-digit sequence number.
You must enter this value on the Cross Connect screen for
the SCM card (where it is labeled VID) to make a
connection through the system.
Summary of Contents for Hotwire ATM Line Cards 8335
Page 6: ...Contents iv February 2003 8335 A2 GB20 70...
Page 14: ...1 About the Hotwire ATM Line Cards 1 6 February 2003 8335 A2 GB20 70...
Page 66: ...3 Configuration 3 44 February 2003 8335 A2 GB20 70...
Page 104: ...5 Diagnostics 5 18 February 2003 8335 A2 GB20 70...
Page 110: ......