7. Monitoring and Troubleshooting
7-20
May 2002
8700-A2-GB20-40
Fields on this screen include:
Viewing Inband Management Statistics
The Inband Management Statistics screen allows you to monitor the Inband
Management Channel (IMC).
NOTE:
The Inband Management Statistics screen is only available for Model 8779
Termination Units.
To view Inband Management Statistics, follow this menu selection sequence:
Main Menu
→
Status
→
Performance Statistics
→
Inband Management
Statistics
Field . . .
Contains . . .
Current Interval
Timer
The number of seconds which have elapsed in the current
15-minute interval. Maximum value is 900 seconds (15 minutes).
This counter is reset every 15 minutes. When zero, the port is
disabled.
Payload Rate
The rate of data transfer.
DSL Line Rate
The rate of the DSL line.
main/status/performance/inband
Slot: 4: Model: 8779
INBAND MANAGEMENT STATISTICS
Inband Management Type: PPP Inband Management TimeSlot: 1
Inband Management Port: 3
-------------------------------------------------------------------------------
TX Frames TX Octets RX Frames RX Octets
Total: 45354 357 9576 467
-------------------------------------------------------------------------------
ESC for previous menu MainMenu Exit
Clr LOS at DSL, Pt 1
Summary of Contents for Hotwire 8777
Page 22: ...2 Using the Asynchronous Terminal Interface 2 10 May 2002 8700 A2 GB20 40 ...
Page 36: ...3 Initial Startup and Configuration 3 14 May 2002 8700 A2 GB20 40 ...
Page 44: ...4 Cross Connecting Ports 4 8 May 2002 8700 A2 GB20 40 ...
Page 52: ...6 Security 6 6 May 2002 8700 A2 GB20 40 ...
Page 96: ...9 Transferring Firmware and Configurations Using TFTP 9 6 May 2002 8700 A2 GB20 40 ...
Page 148: ...C Connector Pin Assignments C 4 May 2002 8700 A2 GB20 40 ...
Page 150: ...D Technical Specifications D 2 May 2002 8700 A2 GB20 40 ...