Cooling and
Air Handling
The internal fans are installed in the chassis to provide cooling.
A built-in feature shuts off power to the circuit cards if a chassis
overheats because of fan failure. If the temperature in the chassis
reaches 70
°
C, power to the cards in the chassis is turned off
automatically. Power is turned on when the temperature drops below
60
°
C.
Operating
Environment
Ambient Temperature for system: 32
°
to 122
°
F (0
°
to 50
°
C)
Ambient Temperature for chassis only: 32
°
to 140
°
F (0
°
to 60
°
C)
Relative Humidity: 15% to 99% noncondensing
Shock and vibration sufficient to withstand normal shipping
External
Clocking
With an SCP card installed, the following clock rates are supported over
the Clock A and Clock B connectors:
2048 KHz (E1)
1544 KHz (T1)
64/8 KHz (standard BITS)
64/8/0.4 KHz (standard BITS plus 400 Hz)