background image

12

 September 

2002

6390-A2-GK40-00

Building a Management PVC to the Model 8355 Line Card in an 
8820 GranDSLAM Network

Before attempting to download software to the Hotwire 6390 ReachDSL modem, 
you must first build a management Permanent Virtual Circuit (PVC) through the 
DSLAM (including the SCM card). To do this, you must create VPI 0, VCI 33 on the 
Model 8355 line card port connected to the 6390 modem to be downloaded (see 

Figure 1, Network View of Hotwire 6390 ReachDSL Modem Software Download in 
an 8820 GranDSLAM System

, and the procedure on next page). 

In DHCP mode (default mode), the 6390 modem discovers the IP address via the 
DHCP server. However, you can also choose to configure a static IP address 
(Static mode) using the mgmtpvc command (see 

Table 1, Hotwire ReachDSL 

6390 Modem Commands

) via a PC attached to the 6390 modem’s Ethernet port. 

The PC must have an IP address of 135.26.6.xxx with a Class C subnet mask.

For more information on the Model 8355 line card, see the 

Hotwire ATM Line 

Cards, Models 8335, 8355, 8365, and 8385, User’s Guide

, Document Number 

8335-A2-GB20.

Figure 1.

Network View of Hotwire 6390 ReachDSL Modem Software Download in 
an 8820 GranDSLAM System

ALARMS

Major Minor

Fan

B

A

POWER

SERIAL

SMCM

CLOCK

A

ALARM

2

4

6

8

10

12

14

16

18

1

3

5

7

9

11

13

15

17

LAN/WAN  SLOT

B

CLOCK

B

A

SERIAL

MCC

AC

ALARM

48V R

TN

48V NEG

POWER ENTRY MODULE

LEFT UNIT: LINE A

RIGHT UNIT: LINE B

WARNING! POWER MUST BE DISCONNECTED AT THE S

OURCE

BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODUL

E

48V R

T

N

48V NEG

POWER ENTRY MODULE

LEFT UNIT: LINE A

RIGHT UNIT: LINE B

WARNING! POWER MUST BE DISCONNECTED AT THE S

OURCE

BEFORE REMOVING OR INSTALLING THIS PWR ENTRY MODUL

E

ReachD

SL

TST

LINE

ETHER

NET

ALM

PWR

TX/RX

6390

Endpoint

GranDSLAM

TM

8820

VPI=0

VCI=33

ATM

VPI=0

VCI=33

ATM

VPI=0

VCI=33

ATM

ATM

Switch

Router

Ethernet

Windows

NT

Windows

2000

Unix

Management

Network

Customer

Network

IP = xxxx

02-17319

1483 Routed

Encapsulation

IP Address

Gateway

Summary of Contents for Hotwire 6390

Page 1: ...ubleshooting 5 Increasing the Number of End User Systems 6 Optional ReachDSL Modem Wall Placement 8 ReachDSL Modem Hardware Template 9 Hotwire 6390 ReachDSL Modem Commands 10 Downloading Hotwire 6390 ReachDSL Modem Software 11 Building a Management PVC to the Model 8355 Line Card in an 8820 GranDSLAM Network 12 Building a Management PVC through the 4200 GranDSLAM System 14 Downloading Software to ...

Page 2: ...r telephone wiring The ReachDSL technology Operates over existing copper wire with existing telephone jacks Uses an inline phone filter on the modem s PHONE jack Includes a second line pass through from the ReachDSL modem s LINE jack to PHONE jack to accommodate an attached 2 line telephone Provides adaptive data rates to dynamically adapt and allocate bandwidth to optimize applications Refer to t...

Page 3: ... user system is used to represent any PC with an Ethernet connection and ReachDSL based service RJ11 wall jack is used to represent either an RJ11 or an RJ14 wall jack The RJ14 wall jack is used for a phone with two lines Service provider is used to represent any Internet Service Provider ISP or remote LAN access provider 02 17237 ReachDSL Modem Customer Premises CP DSL POTS Standard Ethernet Cabl...

Page 4: ...ETHERNET ALM PWR TX RX 01 17003 Power green Alarm red Test yellow Transmit Receive green Ethernet Link green DSL Line green LED Condition Status PWR ON ReachDSL modem has power ALM OFF ON No active alarms An alarm condition exists TST OFF ON No active tests The TST LED is on during the power on self test and during a test initiated by the service provider LINE ON OFF The DSL link is active and rea...

Page 5: ...s Connectors on page 6 LINE LED is off Verify that the DSL LINE cable is securely installed on both ends If the problem continues contact the service provider Verify that the line has dial tone If there is no dial tone contact the service provider LINE LED is on and there is no data transmission The DSL link has been established but there is no data transmission Verify the Ethernet connection If t...

Page 6: ...er DSL port and the Hotwire ReachDSL Modem supports up to 256 MAC entries Cables Connectors Standard twisted pair CAT3 or better cables are recommended The LINE and PHONE interface connectors use 6 pin non keyed modular plugs RJ11 or RJ14 6 pin connectors can be used Line Phone Connectors The LINE and PHONE jack pinouts are either filtered or unfiltered for POTS Pin Function 1 Not used 2 Ring 2 op...

Page 7: ...o connect the DSL modem to an uplink port on an Ethernet hub or PC with an Ethernet NIC card use the straight through connection 8 Pin Straight through Connection Pin Function 1 10BaseT RXD 2 10BaseT RXD 3 10BaseT TXD 4 5 Not used 6 10BaseT TXD 7 8 Not used 98 16055a 8 Pin Plug Ethernet Cable Pin 1 Pin 8 ...

Page 8: ...hors Drill and 3 16 drill bit for the plastic anchors Screwdriver A template with the dimensions for the two screws is provided See ReachDSL Modem Hardware Template on page 9 Procedure To mount the Hotwire 6390 ReachDSL Modem 1 Use a drill to install the plastic anchors 2 Use a screwdriver to install the screws Do not install the screws flush with the wall Leave enough clearance to hang the modem ...

Page 9: ...6390 A2 GK40 00 September 2002 9 ReachDSL Modem Hardware Template 12 95 cm or 5 10 02 17014 01 Top Bottom ...

Page 10: ...irmware Revision Hardware Revision DSP Revision logoff None Terminates the Telnet session mgmtpvc dhcp IP address gateway No argument dhcp or ip address dhcp Example mgmtpvc dhcp IP address gateway Example mgmtpvc 135 26 95 1 135 26 95 6 Configures or displays the management PVC Current configuration Configures the management PVC The management PVC acquires its address using DHCP The management PV...

Page 11: ...8820 GranDSLAM network with a Model 8355 Line Card or a 4200 GranDSLAM network See the following for procedures Building a Management PVC to the Model 8355 Line Card in an 8820 GranDSLAM Network on page 12 Building a Management PVC through the 4200 GranDSLAM System on page 14 Downloading Software to the ReachDSL Modem on page 15 upgrade IP address m e remote file name IP address m or e m e Remote ...

Page 12: ...ss of 135 26 6 xxx with a Class C subnet mask For more information on the Model 8355 line card see the Hotwire ATM Line Cards Models 8335 8355 8365 and 8385 User s Guide Document Number 8335 A2 GB20 Figure 1 Network View of Hotwire 6390 ReachDSL Modem Software Download in an 8820 GranDSLAM System ALARMS Major Minor Fan B A POWER SERIAL SMCM CLOCK A ALARM 2 4 6 8 10 12 14 16 18 1 3 5 7 9 11 13 15 1...

Page 13: ...ine card as shown below 3 Select the Cross Connect Sorted by Slot screen from SCM card Follow this menu selection sequence Configuration ATM Switch Cross Connect Sorted by Slot A E B B 4 Define the custom cross connect table on the SCM card using the last three digits of the Connection Serial Number CSN from the Model 8355 line card Cross Connect screen In this example use the 002 portion of the 1...

Page 14: ...ic mode using the mgmtpvc command see Table 1 Hotwire ReachDSL 6390 Modem Commands via a PC attached to the 6390 modem s Ethernet port The PC must have an IP address of 135 26 6 xxx with a Class C subnet mask For more information on the GranDSLAM 4200 and CLI commands see the GranDSLAM 4200 ATM Stackable DSLAM User s Guide Document Number 4200 A2 GB20 Figure 2 Network View of Hotwire 6390 ReachDSL...

Page 15: ...n the upstream ATM network NT and Port 1 LT using the ENT CRS VC command For example type ENT CRS VC TAMPA NTVCL 1 33 LTVCL 1 1 1 1 0 33 100 IS 5 Define a management PVC path across the ATM network to reach the GranDSLAM 4200 1 33 uplink management PVC using 1483 routed encapsulation 6 Ping the Hotwire 6390 ReachDSL Modem Management IP address assigned by the DHCP server DHCP mode or manually Stat...

Page 16: ... Approvals FCC Part 15 CISPR 22 Other Certifications Class B digital device Class B Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 0 C to 40 C 32 F to 104 F 30 C to 70 C 22 F to 158 F 5 to 95 noncondensing Withstands normal shipping and handling Heat Dissipation 2 35 watts at 5 0 VDC nominal i...

Page 17: ...pany representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include your na...

Page 18: ... 6390 A2 GK40 00 ...

Reviews: