Paradyne Hotwire 6371 Installation Instructions Manual Download Page 9

9

Installing the Hotwire 6371 RADSL Router

Place the RADSL router on a flat surface, with clearance for the rear connectors. For 
router cable pin assignments, refer to 

Cables and Connectors

 on page 17.

Connecting the DSL Line in a Home Environment (Phone and Router in 
the Same Location)

For the DSL connection, use the supplied RJ11 6-pin cable. You will also need a multiple 
line adapter and a filter (see 

Phone Filters

 on page 3).

Procedure

 

1. Insert a multiple line adapter into the wall jack. 

2. Insert one end of the cable into the DSL jack on the router. 

3. Insert the other end of the cable into one of the jacks (Line 1 or Line 2) on the 

multiple line adapter. 

4. Insert the line cord from the LINE jack on the filter into the empty jack on the 

multiple line adapter.

5. Insert the phone line cord from the phone into the PHONE jack on the filter.

POWER

CONSOLE

DSL

ETHERNET

01-17018

LINE

PHO

NE

6371 RADSL Router

Multiple
Line
Adapter

Filter

Summary of Contents for Hotwire 6371

Page 1: ...Service and Training Information 28 Hotwire 6371 RADSL Router Overview The Hotwire 6371 RADSL Rate Adaptive Digital Subscriber Line Router is a component in the Hotwire DSL Access system which intero...

Page 2: ...same pair of copper wires when a POTS splitter is installed near the demarcation point for all telephones on the same POTS line as DSL When a Hotwire 5030 POTS Splitter is used at both ends of the lo...

Page 3: ...ices for example a phone and fax machine can be supported using a single filter if a multiple line adapter is used 00 16570 02 Punchdown Block or NID DSL Jack DSL Router Customer Premises CP DSL Ether...

Page 4: ...PARADYNE 1 800 727 2396 Outside the U S A call 1 727 530 8623 For more information about Hotwire DSL Routers refer to the following document 6371 A2 GB20 Hotwire DSL Routers User s Guide To install a...

Page 5: ...meet EIA TIA 568 specifications with 24 AWG 5 mm or 26 AWG 4 mm Ethernet wiring Shielded twisted pair wiring CAT5 or better The CAT5 wiring must meet EIA TIA 568 specifications with 24 AWG 5 mm or 26...

Page 6: ...residential locations Procedure 1 Access the punchdown block or NID 2 Disconnect the DSL access pair from the local loop WARNING Do not continue unless the DSL access line from the local loop has bee...

Page 7: ...e following example shows a NID without a POTS splitter It includes an existing POTS pair and a second DSL pair is installed for DSL access DSL POTS Access from Local Loop Wiring to DSL Jack Telephone...

Page 8: ...edure 1 Wiring can be run from the punchdown block or NID to a new or existing wall jack Match the pair colors on both ends 2 Label the DSL jack 3 Reconnect the DSL access pair at the punchdown block...

Page 9: ...e line adapter and a filter see Phone Filters on page 3 Procedure 1 Insert a multiple line adapter into the wall jack 2 Insert one end of the cable into the DSL jack on the router 3 Insert the other e...

Page 10: ...s Use the supplied RJ11 6 pin cable for the DSL connection Procedure 1 Insert one end of the cable into the DSL jack on the router 2 Insert the other end of the cable into the wall jack POWER CONSOLE...

Page 11: ...ernet crossover cable To support multiple end user systems refer to Increasing the Number of End User Systems on page 16 To connect a PC using a crossover cable Insert one end of the crossover cable i...

Page 12: ...f the router To set up the VT100 terminal or PC for local configuration and to access the router refer to Configuration Setup and Accessing the Router on page 16 Procedure 1 Connect a DB9 adapter to t...

Page 13: ...OWER jack on the router 2 Plug the transformer into an AC outlet Installation of the hardware is now complete When the power cord is installed the router goes through a power on self test POWER CONSOL...

Page 14: ...T LED is also on during a download An alarm condition exists No alarms have been detected by the router TST ON OFF The TST LED is on during the power on self test during a test initiated by the servic...

Page 15: ...ink has been established but data is not being transmitted Verify the Ethernet connection at both ends If the problem persists contact the service provider DSL and Ethernet LEDs are on but no data is...

Page 16: ...password prompt enter the factory default Password of abc123 3 At the next prompt for System ID the factory default is CUSTOMER Optionally enter show system to display hardware firmware information an...

Page 17: ...ence information Use a CAT3 or better cable for the DSL line The DSL interface uses a 6 pin non keyed modular plug RJ11 6 Pin Connector Pin Function 1 2 Not used 3 DSL Ring 4 DSL Tip 5 6 Not used 98 1...

Page 18: ...ction 1 10 100BaseT TX D 2 10 100BaseT TX D 3 10 100BaseT RX D 4 5 Not used 6 10 100BaseT RX D 7 8 Not used 98 16055a 8 Pin Plug Ethernet Cable Pin 1 Pin 8 10 100BaseT TX D 10 100BaseT TX D 10 100Base...

Page 19: ...o DB9 Adapter Plug Pin Circuit Direction 1 Not used 2 DTR Input to Console port 3 TXD Input 4 5 Signal Ground 6 RXD Output 7 DSR Output 8 Not used Modular Pin Circuit DB9 Pin 1 RTS 7 2 DTR 4 3 TXD 3 4...

Page 20: ...ect size drill bit for the anchors Screwdriver A template with the dimensions for the three screws is provided See RADSL Router Hardware Template on page 21 Procedure To mount the RADSL router 1 Drill...

Page 21: ...21 RADSL Router Hardware Template Front LEDs 98 16171 5 43 7 55 To Bottom Hole...

Page 22: ...50 Hz 120 VAC 10 60 Hz or 230 VAC 10 50 60 Hz Output 18 VDC nominal at 0 8A Unit Power Consumption 5 5 watts nominal Approvals FCC Part 15 CISPR 22 Safety Certifications Class B Subpart B digital dev...

Page 23: ...ction authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnec...

Page 24: ...in the devices not ringing in response to an incoming call In most but not all areas the sum of the RENs should not exceed five 5 0 To be certain of the number of devices that may be connected to the...

Page 25: ...that the equipment meets telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department...

Page 26: ...8545 126th Avenue North Largo FL 33773 1502 Phone 727 530 2000 The authority to operate this equipment is conditioned by the requirement that no modifications will be made to the equipment unless the...

Page 27: ...gned for use within certain voltage limits as amended by Directive 93 68 EEC Directive 89 336 EEC Council Directive of 3 May 1989 on the approximation of the laws of the member states relating to Elec...

Page 28: ...a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to...

Reviews: