Paradyne Hotwire 6321 Installation Instructions Manual Download Page 6

 6

Installing the Hotwire 6321/6322 IDSL Router

Place the Hotwire 6321/6322 IDSL Router on a flat surface with clearance for the rear
connectors.

NOTE:

The following illustrations show the Hotwire 6322 IDSL Router with a 4-port
Ethernet hub. The Hotwire 6321 IDSL Router is identical except that it has one
Ethernet port.

"

Procedure

1. Use the RJ11 6-pin cable for the DSL connection. Insert one end of the cable into

the jack labeled DSL. Insert the other end into the wall jack labeled DSL.

00-16669

DSL

Jack

POWER

CONSOLE

DSL

2

1

ETHERNET

3

4

6322 IDSL Router

I f  you are installing a . . .

Then go to . . .

Hotwire 6321 IDSL Router

page 7

Hotwire 6322 IDSL Router

page 8

Summary of Contents for Hotwire 6321

Page 1: ...ocumentation for specific topics and print only what you need reducing the waste of surplus printing It also helps us maintain competitive prices for our products Complete documentation for this product is available at www paradyne com Select Library Technical Manuals Hotwire DSL and MVL Systems Select the following document 6371 A2 GB20 Hotwire DSL Routers User s Guide To order a paper copy of a ...

Page 2: ...nternet or corporate LAN access over a combination of traditional twisted pair copper telephone wiring and ISDN transport such as T1 or fiber These products have three data channels that are configurable for a total of 144 kbps Network Overview with a Hotwire 6321 IDSL Router 00 16667 Punchdown Block or NID DSL Jack 6321 IDSL Router Customer Premises CP DSL Ethernet Crossover Cable Ethernet Cable ...

Page 3: ...contains the following Model 6321 or Model 6322 IDSL Router DSL interface cable with RJ11 modular plugs Power cord with power transformer Wiring and Cables Needed You will need the following wiring and standard connectors with this product Standard RJ11 wall jack for the DSL cabling DSL cabling New or existing unshielded twisted pair wiring CAT3 or better The CAT3 wiring must meet EIA TIA 568 spec...

Page 4: ...p terminates at the punchdown block or NID Wiring must be connected from the customer premises side of the punchdown block or the NID to an RJ11 jack Typically the punchdown block is installed in commercial locations and the NID is installed in residential locations Procedure 1 Access the punchdown block or NID WARNING Do not continue unless the DSL access line from the local loop has been disconn...

Page 5: ...e necessary to install a standard single RJ11 jack or replace a single jack with a double RJ11 jack 99 16589 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises DSL Local Loop Demarcation Point DSL Twisted pair Wiring DSL Router Procedure 1 Wiring can be run from the punchdown block or NID to a new or existing wall jack Match the pair colors on both ends 2 Label the DSL jack 3 Re...

Page 6: ...Ethernet hub The Hotwire 6321 IDSL Router is identical except that it has one Ethernet port Procedure 1 Use the RJ11 6 pin cable for the DSL connection Insert one end of the cable into the jack labeled DSL Insert the other end into the wall jack labeled DSL 00 16669 DSL Jack POWER CONSOLE DSL 2 1 ETHERNET 3 4 6322 IDSL Router If you are installing a Then go to Hotwire 6321 IDSL Router page 7 Hotwi...

Page 7: ...through cable to the external hub s UPLINK connection this connection requires a crossover cable POWER CONSOLE DSL ETHERNET 00 16670 Ethernet Line Ethernet Hub Ethernet Straight through Cable 8 7 6 5 4 3 2 1 6321 IDSL Router or H For a 6321 IDSL Router use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Interface Card NIC installed POWER CONSOLE DSL ETHERNET ...

Page 8: ...Connectors on page 13 3 The Console port acts as a DCE and uses an 8 pin straight through cable for the connection to a VT100 compatible terminal or a PC running a terminal emulation program This is an optional connection used only for local configuration of the DSL router For details refer to Local Console Access on page 12 Connect the DB9 adapter to the PC and connect the cable to a PC or laptop...

Page 9: ... installed the IDSL router goes through a power on self test Power On When power is applied the Hotwire 6321 6322 IDSL Router performs self diagnostics and the PWR LED is on The self diagnostics includes a power on self test During the power on self test all of the LEDs turn on for one second TST DSL ETHERNET ALM PWR TM 00 16675 Power green Alarm red Test yellow Digital Subscriber Line green Ether...

Page 10: ...No active alarms An alarm condition exists TST OFF ON No active tests The TST LED is on during the power on self test and during a test initiated by the service provider DSL Blinking ON OFF The IDSL router is establishing the active DSL link The LED blinks on and off about five times per second The DSL link is now active and ready to transmit and receive data The DSL link has not been established ...

Page 11: ... been established but there is no data transmission First verify the Ethernet connection If the problem persists contact the service provider DSL ETHERNET LEDs are on and there is no data transmission The DSL link and the Ethernet link have been established but there is no data transmission If the problem continues contact the service provider ETHERNET LED is off Verify that the Ethernet cable is ...

Page 12: ... prompt for System ID the factory default is CUSTOMER Type show system to display hardware firmware information and Selftest Results optional Refer to the Hotwire DSL Routers User s Guide for configuration settings and command line entries Increasing the Number of End User Systems The Hotwire 6321 6322 IDSL Router can support differing numbers of end user systems depending on the functions that ar...

Page 13: ...onnector uses a 6 pin non keyed modular plug RJ11 6 Pin Connector Pin Function 1 2 Not used 3 DSL Ring 4 DSL Tip 5 6 Not used H The Console connector uses 8 pin non keyed modular plugs and a DB9 adapter See Hotwire 6321 6322 IDSL Router Configuration Setup on page 12 RJ45 8 Pin Connector Pin Circuit Direction 1 Not used 2 DTR Input to Console port 3 TXD Input 4 Signal Ground 5 Signal Ground 6 RXD ...

Page 14: ...00BaseT TX D 3 10 100BaseT RX D 4 5 Not used 6 10 100BaseT RX D 7 8 Not used To connect a Hotwire 6321 IDSL Router to a PC with an Ethernet NIC card installed or a Hotwire 6322 IDSL Router to an external hub use an Ethernet crossover cable 10 100BaseT TX D 10 100BaseT TX D 10 100BaseT RX D Not Used Not Used 10 100BaseT RX D Not Used Not Used 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 10 100BaseT TX D 10 100B...

Page 15: ...th molly bolts Drill and 3 16 drill bit for the molly bolts Screwdriver A template with the dimensions for the three screws is provided See IDSL Router Hardware Template on page 16 Procedure To mount the IDSL router 1 Use a drill to install the plastic anchors molly bolts 2 Use a screwdriver to install the screws Do not install the screws flush with the wall Leave enough clearance to hang the IDSL...

Page 16: ...16 IDSL Router Hardware Template Front LEDs 98 16171 5 43 7 55 To Bottom Hole ...

Page 17: ... 8 watts nom Approvals FCC Part 15 Safety Certifications Class B Subpart B digital device Refer to equipment s label for approvals on product Physical Environment Operating temperature Storage temperature Relative humidity Shock and vibration 32 F to 104 F 0 C to 40 C 4 F to 158 F 20 C to 70 C 5 to 95 noncondensing Withstands normal shipping and handling Interface Connectors DSL Interface Console ...

Page 18: ...ection authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action pri...

Page 19: ...perate this equipment is conditioned by the requirement that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful i...

Page 20: ...pany representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th Ave N Largo FL 33773 or send e mail to userdoc paradyne com Include the number and title of this document in your correspondence Please include your na...

Reviews: