background image

 18

Declaration of Conformity

This Declaration of Conformity is made by Paradyne Corporation pursuant to Parts 2
and 15 of the Federal Communications Commission’s Rules. This compliance
information statement pertains to the following products:

Trade Name:

Hotwire

Model Number:

5620-A2-200

This device complies with Part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and 
(2) this device must accept any interference received, including interference that may
cause undesired operation.

The name, address, and telephone number of the responsible party is given below:

Paradyne Corporation
8545 126th Avenue North
Largo, FL 33773-1502
Phone: (727) 530-2000

The authority to operate this equipment is conditioned by the requirement that no
modifications will be made to the equipment unless the changes or modifications are
expressly approved by Paradyne Corporation.

In order to maintain compliance with Part 15, FCC rules, the clamp-on ferrite chokes
must be installed on the Ethernet cable and the Power cable in accordance with the
installation instructions.

Summary of Contents for Hotwire 5620 RTU

Page 1: ...ment Document Number Document Title 5030 A2 GN10 Hotwire 5030 POTS Splitter Customer Premises Installation Instructions 5038 A2 GN10 Hotwire 5038 Distributed POTS Splitter Customer Premises Installati...

Page 2: ...same POTS line as DSL or H A Hotwire 5038 Distributed POTS Filter is installed on each telephone on the same POTS line as DSL DSL Access with a Hotwire 5030 or 5038 POTS Splitter Copper pairs run from...

Page 3: ...tions Existing Wiring POTS DSL Access with a Hotwire 5038 Distributed POTS Splitter When a Hotwire 5038 Distributed POTS Splitter is used one 5038 Distributed POTS Splitter is installed as a filter fo...

Page 4: ...Punchdown Block or NID DSL Jack RTU Customer Premises CP POTS DSL Ethernet Crossover Cable Ethernet Cable or Central Office CO Demarcation Point Local Loop Hub New Wiring Connections Existing Wiring P...

Page 5: ...residential locations Procedure 1 Access the punchdown block or NID WARNING Do not continue unless the DSL access line from the local loop has been disconnected at the NID or punchdown block Refer to...

Page 6: ...n the following example a NID is used without a POTS splitter It includes an existing POTS line and a second pair installed for DSL access DSL POTS Access from Local Loop Wiring to DSL Jack Telephone...

Page 7: ...SL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring RTU Procedure 1 Wiring can be run from the punchdown block or NID to...

Page 8: ...20 RTU is installed on the same line as POTS a Hotwire 5038 Distributed POTS Splitter can be used as a filter One Hotwire 5038 Distributed POTS splitter is installed as a filter for each telephone as...

Page 9: ...hub or 97 15303 01 Ethernet Hub Ethernet Line POWER ETHERNET DSL Hotwire RTU Ethernet Cable Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Interface Card N...

Page 10: ...5 Insert the power cord s round end into the jack labeled POWER Attach the ferrite choke on the power cord as closely as possible to the RTU Pass the power cable through the ferrite choke twice creat...

Page 11: ...nd 3 16I drill bit for the molly bolts Screwdriver A template with the dimensions for the three screws is provided See RTU Hardware Template on page 12 Procedure To mount the RTU 1 Use a drill to inst...

Page 12: ...12 RTU Hardware Template Front LEDs 98 16171 5 43 7 55 To Bottom Hole...

Page 13: ...on self test After a successful self test the LEDs should appear as indicated in BOLD in the Condition column below LED Condition Status PWR ON RTU has power ALM OFF ON No active alarms An alarm condi...

Page 14: ...he NSP DSL and Ethernet LEDs are on and there is no data transmission The DSL and Ethernet links have been established but there is no data transmission If the problem continues contact the NSP Ethern...

Page 15: ...Pin Straight Through Connection Pin Function 1 10BaseT TX D 2 10BaseT TX D 3 10BaseT RX D 4 5 Not used 6 10BaseT RX D 7 8 Not used To connect the RTU directly to a PC with an Ethernet NIC card use an...

Page 16: ...20 Vac 10 60 Hz or 230 Vac 10 50 60 Hz Output 15 Vdc nominal minimum 0 6A Approvals FCC Part 15 CISPR 22 Safety Certifications Class B Subpart B digital device Class B Refer to equipment s label for a...

Page 17: ...ction authorities to ensure compliance 7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnec...

Page 18: ...ust accept any interference received including interference that may cause undesired operation The name address and telephone number of the responsible party is given below Paradyne Corporation 8545 1...

Page 19: ...not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations made by the user t...

Page 20: ...r to speak with a company representative Within the U S A call 1 800 870 2221 Outside the U S A call 1 727 530 2340 Trademarks All products and services mentioned herein are the trademarks service mar...

Reviews: