Model 5246 RTU Technical Specifications
Item
Specification
*
Height x Width x Depth
1.35
″
x 6.00
″
x 8.75
″
(3.43 cm x 15.35 cm x 22.23 cm)
Weight
1 lb. 1 oz. (0.48 kg)
Power
Class 2 Transformer normal
service input voltage range
Input:
100 Vac, 50 Hz; 120 Vac, 60 Hz; or
230 Vac, 50/60 Hz
Output:
15 Vdc nominal (+10%), minimum 0.6A
Approvals
FCC Part 15
CISPR 22
Safety Certifications
Class B Subpart B digital device
Class B
Refer to equipment’s label for approvals on product.
Physical Environment
Operating temperature
Storage temperature
Relative humidity
Shock and vibration
32
°
F to 104
°
F ( 0
°
C to 40
°
C )
– 4
°
F to 158
°
F ( –20
°
C to 70
°
C )
5% to 95% ( noncondensing )
Withstands normal shipping and handling
Heat Dissipation
40.9 Btu/hr. (max.) at nominal input voltage
Interface Connectors
DSL Interface
Ethernet Type II Frame
RJ11 6-pin
10BaseT 8-pin
*
Technical Specifications subject to change without notification.
Important Safety Instructions
1. Read and follow all warning notices and instructions marked on the product or
included in the manual.
2. Slots and openings in the cabinet are provided for ventilation. To ensure reliable
operation of the product and to protect it from overheating, these slots and
openings must not be blocked or covered.
3. Do not allow anything to rest on the power cord and do not locate the product
where persons will walk on the power cord.
4. Do not attempt to service this product yourself, as opening or removing covers
may expose you to dangerous high voltage points or other risks. Refer all servicing