background image

TM

 1

HotWire 5246 Remote Termination Unit (RTU)
Customer Premises
Installation Instructions

Document Number 5246-A2-GN10-00

October 1997

Before You Begin

An optional POTS (Plain Old Telephone Service) splitter is available for the 5246 RTU.
When a POTS splitter is installed, the telephone and 5246 RADSL (Rate Adaptive
Digital Subscriber Line) RTU can function at the same time over the same pair of
copper wires. In order to confirm the RTU installation, the POTS splitter should be
installed first. To install a POTS splitter, refer to the appropriate POTS splitter
document:

Document Number

Document Title

5030-A2-GN10

HotWire 5030 POTS Splitter Customer Premises 
Installation Instructions

5034-A2-GN10

HotWire 5034 Indoor POTS Splitter Customer Premises
Installation Instructions

Wiring and Cables Needed

The following wiring and standard connectors are used with this product:

New or existing unshielded twisted-pair wiring (CAT3 or better). The CAT3 wiring
must meet EIA/TIA-568 specifications with 24 AWG (.5 mm) or 26 AWG (.4 mm).

Standard RJ11 wall jack.

Standard Ethernet 8-pin, non-keyed modular plug for a PC or workstation. An
Ethernet straight-through or crossover cable is used. Refer to 

Installing the RTU

,

page 8, for Ethernet cable details.

Package Checklist

Verify that your package contains the following:

Model 5246 Remote Termination Unit (RTU)

DSL interface cable with RJ11 modular plugs

Power cord with power transformer

Ferrite choke

Warranty card

Refer to 

Cables & Connectors

,

 page 14, for standard pin numbers.

Summary of Contents for HotWire 5246

Page 1: ...ises Installation Instructions 5034 A2 GN10 HotWire 5034 Indoor POTS Splitter Customer Premises Installation Instructions Wiring and Cables Needed The following wiring and standard connectors are used...

Page 2: ...ing is connected H From the demarcation point to the CP POTS splitter and H From the demarcation point to the DSL jack 97 15346 01 Punchdown Block or NID DSL Jack RTU New Wiring Connections Existing W...

Page 3: ...hdown Block or NID DSL Jack RTU Customer Premises CP POTS DSL Ethernet Crossover Cable Ethernet Cable or Central Office CO Demarcation Point Local Loop HUB New Wiring Connections Existing Wiring POTS...

Page 4: ...residential locations Procedure 1 Access the punchdown block or NID Disconnect the DSL access pair from the local loop WARNING Do not continue unless the DSL access line from the local loop has been...

Page 5: ...ng POTS line and a second pair installed for DSL access The pair for the POTS line does not need to be disconnected unless a POTS splitter is going to be installed DSL POTS Access from Local Loop Tele...

Page 6: ...that will be connected to the DSL jack Tighten both terminal screws with a flat blade screwdriver DSL POTS Access from Local Loop Wiring to DSL Jack Telephone Network Interface Device NID Ground Tip...

Page 7: ...For pin assignments refer to Cables Connectors page 14 97 15343 01 DSL RJ11 Jack Central Office Punchdown Block or NID Customer Premises POTS DSL Local Loop Demarcation Point DSL Twisted pair Wiring...

Page 8: ...e with clearance for the rear connectors Procedure 1 Use the RJ11 6 pin cable for the DSL connection Insert one end of the cable into the jack labeled DSL Insert the other end into the wall jack label...

Page 9: ...or 97 15303 Ethernet Hub Ethernet Line POW ER ETHERNET D S L Ho tW ire RTU Ethernet Cable H Use an Ethernet crossover cable and connect the other end to a PC with an Ethernet Network Interface Card NI...

Page 10: ...cable and snap the ferrite choke shut Press down on the plastic latch to secure the ferrite choke in place around the cable 5 Insert the power cord s round end into the jack labeled POWER Plug the tra...

Page 11: ...the power on self test After a successful self test the LEDs should appear as indicated in BOLD in the Condition column below LED Condition Status PWR ON RTU has power ALM OFF ON No active alarms An a...

Page 12: ...plug the RTU and reapply power If problem continues contact the NSP DSL LED continues to blink after the power on self test The RTU is attempting to establish the DSL link If the DSL LED continues to...

Page 13: ...ly power watch all LEDs during the power on self test to verify that the PWR LED is functioning TST LED is on A test initiated by the NSP may be active Wait five minutes If the TST LED does not go off...

Page 14: ...Cables Connectors Use standard twisted pair CAT3 or better cables This section is reference information H The DSL interface connector uses a 6 pin non keyed modular plug RJ11 6 Pin Connector Pin Funct...

Page 15: ...D 2 10BaseT TX D 3 10BaseT RX D 4 5 Not used 6 10BaseT RX D 7 8 Not used To connect the RTU directly to a PC with an Ethernet NIC card use an Ethernet crossover cable 10BaseT TX D 10BaseT TX D 10BaseT...

Page 16: ...handling Heat Dissipation 40 9 Btu hr max at nominal input voltage Interface Connectors DSL Interface Ethernet Type II Frame RJ11 6 pin 10BaseT 8 pin Technical Specifications subject to change withou...

Page 17: ...nsformer with a Safety Extra Low Voltage SELV output having a maximum 240 VA available for use in the country of installation 9 In addition since the equipment is to be used with telecommunications ci...

Page 18: ...1 200 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interfe...

Page 19: ...e conditions may not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or alterations ma...

Page 20: ...repair installation documentation or training use one of the following methods H Via the Internet Visit the Paradyne World Wide Web site at http www paradyne com H Via Telephone Call our automated ca...

Reviews: