Using the HotWire Diagnostics Utility
3-2
5100-A2-GB22-10
April 1997
Symptom
Possible Solution
Possible Cause
Experiencing
several errors while
transferring files.
Bad connection to
the CO.
Bad Ethernet card.
Bad Ethernet
cable.
1. Run local Loopback test; see
Running
Loopback Tests
.
2. Run Remote Loopback test.
3. Run Ethernet Loopback test.
4. Attempt to reset the 5170 unit; see
Resetting the RTU
.
5. Contact your customer service
representative.
Cannot connect to
Central Office.
Network Link is
down.
Network cable not
connected.
1. Run a Remote Loopback test; see
Running Loopback Tests
.
2. If Remote Loopback test is successful,
check Link State; see
Viewing
Transmission Statistics and Network
Status
.
3. If link is up, check network cable
connection.
Cannot run
diagnostics. System
hangs.
1. Restart Diagnostic Utility.
2. Contact your customer service
representative.