Paradyne FrameSaver SLV 9126 Installation Instructions Manual Download Page 16

 16

Check Health and Status messages in the left column of the System and Test
Status screen for messages.

Main Menu

Status

System and Test Status

– If 

System Operational

 appears, the Port-1 interface is set up correctly and

is operational.

– If 

System Operational

 does not appear, refer to the status information in

Operation and Maintenance of the User’s Guide.

NOTE:

When any error conditions are detected, a status message will appear at the
bottom right corner of the screen.

Connecting the Modem

1. Insert the RJ11C connector on the modem cable into the Modem/MDM interface.

2. Insert the other end of the cable into the phone service RJ11C jack.

DSX

COM

POWER

MODEM NET

DBM

P
O
R
T

2

P
O
R
T

1

98-16235

RJ11C

Jack

(FrameSaver 9128

Shown)

Verification Check:

If Port Use is set to Terminal (dial-in access):

Dial the modem’s phone number using a remote asynchronous terminal or PC.

Verify that the Main Menu appears.

If Port Use is set to Net Link (SNMP, Telnet, FTP, and trap dial-out):

Dial the modem’s phone number using a PC running PPP or SLIP link protocol.

From the PC, run an IP Ping test to the modem interface.

If your results using either method are unsuccessful, make sure both ends of the
modem cable are properly seated and secured. Then, verify that the modem was
configured correctly (see 

Setting Up the Modem on page 8). Otherwise, refer to the

status information in 

Operation and Maintenance of the User’s Guide.

Proceed to 

Connecting to the ISDN on page 17 if the FrameSaver unit is equipped with

a DBM.

Summary of Contents for FrameSaver SLV 9126

Page 1: ...ver Frame Relay Devices Select the following document 9128 A2 GB20 FrameSaver SLV 9126 9128 User s Guide To request a paper copy of a Paradyne document Within the U S A call 1 800 PARADYNE 1 800 727 2...

Page 2: ...DSX cable Data port cables COM port to terminal or COM port to PC cable Modem cable See the User s Guide for additional information on Troubleshooting Cables Connectors and Pin Assignments Technical S...

Page 3: ...e the POWER jack Make sure the locking tab snaps securely into the jack 2 DSX COM POWER MODEM NET DBM P O R T 2 P O R T 1 POWER P O R T 1 99 16629 Power Cord Transformer Insert the 3 prong plug into a...

Page 4: ...one 2 Insert the DB25 end of the EIA 232 cable into the FrameSaver unit s COM port DSX COM POWER MODEM NET DBM P O R T 2 P O R T 1 To Connect to a PC or Async Terminal COM Port 99 16628 3 Insert the o...

Page 5: ...you can start setting up the unit To load a configuration for editing 1 From the Main Menu press the down arrow key twice so the cursor is on Configuration 2 Press Enter to display the Configuration m...

Page 6: ...The results of the self test appears directly under the screen title If any failure messages appear reset the unit by disconnecting then reconnecting the power cord The unit will perform the self test...

Page 7: ...nfigurations Setting Frame Relay Characteristics When installing a FrameSaver SLV NAM frame relay characteristics must be configured for the network and data ports 1 Select the interface s frame relay...

Page 8: ...d Subnet Mask if it is different from the Node s Change Link Protocol to SLIP if necessary PPP is the default setting 3 Save the configuration Setting Up Call Directories if Trap Dial Out Is Desired 1...

Page 9: ...several automatic configuration features Frame Relay Discovery and configuration is one of these features Main Menu Auto Configuration The default discovery mode is 1MPort In this mode for each DLCI...

Page 10: ...orrectly and is operational If not make sure both ends of the network cable are properly seated and secured Verify that the network physical options are configured correctly Main Menu Configuration Ne...

Page 11: ...gured for single site backup Modify the HQ_Site Link Profile that Automatic Backup Configuration created to add a phone number Configure the remote unit to originate calls to the central site A BRI DB...

Page 12: ...ers entered Originating Unit Answering Unit Outbound phone number Valid characters include Numbers 0 9 Special characters and Spaces Parentheses Inbound Calling ID1 and ID2 These are the phone numbers...

Page 13: ...om Multiplexed to Standard The DLCI in connections Update DLCI usage as follows prompt appears 5 Select the Delete EDLCI Connections and Make a Mgmt Only PVC option PVC connections for the selected DL...

Page 14: ...hile the test is running In Progress is displayed in the Status field When the test is finished Alive Latency nn ms should appear as the Status nn being the amount of time the test took in millisecond...

Page 15: ...s If any DSX 1 messages appear refer to the status information in Operation and Maintenance of the User s Guide In the User s Guide see Operation and Maintenance for additional status information and...

Page 16: ...POWER MODEM NET DBM P O R T 2 P O R T 1 98 16235 RJ11C Jack FrameSaver 9128 Shown Verification Check If Port Use is set to Terminal dial in access Dial the modem s phone number using a remote asynchr...

Page 17: ...Inv SPID for a BRI DBM is displayed verify that you entered ISDN physical options correctly Check backup setup and that data can be passed between DBMs Select Test then ISDN Call PVC Tests Main Menu T...

Page 18: ...aintenance for additional status information and Troubleshooting for additional troubleshooting information Check That Data is Being Received 1 Return to the Main Menu then select Status 2 Select Perf...

Page 19: ...r covered 4 Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord 5 Do not attempt to service this product yourself as opening or remo...

Page 20: ...ainst harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance w...

Page 21: ...fy you in advance But if advance notice is not practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make cha...

Page 22: ...B1 and BRI B2 each with one Service Profile Identification SPID number and one local phone number Busy Fixed Call Forwarding for the answering system typically the central site system is recommended...

Page 23: ...ier Any repairs or alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request to disconnect the equipment Users should ensure for...

Page 24: ...70 2221 Outside the U S A call 1 727 530 2340 Document Feedback We welcome your comments and suggestions about this document Please mail them to Technical Publications Paradyne Corporation 8545 126th...

Reviews: