5. Operation and Maintenance
9123-A2-GB20-20
August 2001
5-17
Test Status Messages
These test messages appear in the right column of the System and Test Status
screen. You have the option of allowing the test to continue or aborting the test.
See
, for more information on tests, including how to
start and stop them.
Table 5-8.
Test Status Messages
Message
What It Indicates
DCLB Active, [Net1-FR1/Port-1]
A Data Channel V.54 Loopback (DCLB) is active on
the T1 network frame relay link, or on the data for
the user data port.
DTE External LB Active, Port-1
An external DTE Loopback is running on the user
data port.
DTE Init. Ext LB Active, Port-1
The DTE has initiated an external DTE Loopback
on the user data port.
DTPLB Active, Port-1
A Data Terminal Payload Loopback (DTPLB) is
active for the specified slot and port.
Lamp Test Active
The Lamp Test is active, causing the LEDs on the
faceplate to flash on and off.
LLB Active, Network 1
A network Line Loopback (LLB) is active on the
specified interface.
Monitor Pttn Active, DLCI nnnn,
frame_relay_link
The unit is monitoring a test pattern on the specified
DLCI on the specified frame relay link.
Monitor Pttn Active, [Interface]
A Monitor Pattern test is active on the specified
interface.
This test cannot be activated on user data ports that
have Port Use set to Frame Relay.
No Test Active
No tests are currently running.
PLB Active, Network 1
A Payload Loopback (PLB) is active on the
specified interface.
PVC Loopback Active, DLCI nnnn,
frame_relay_link
A PVC Loopback is active on the specified DLCI on
the frame relay link.
RLB Active, Network 1
A network Repeater Loopback (RLB) is active on
the specified interface.
Send Pttn Active, DLCI nnnn,
frame_relay_link
The unit is monitoring the selected test pattern on
the specified DLCI for the interface.
Send Pttn Active, [Interface]
A Send Pattern test is active on the specified
interface.
This test cannot be activated on user data ports that
have Port Use set to Frame Relay.
1
nnnn indicates a DLCI number of 16 through 1007.
2
frame relay link is one of the following:
– Net1-FR1. The frame relay link specified for the network interface, Network 1.
– Port-1. The frame relay link associated with the user data port.
Summary of Contents for FrameSaver FLEX 9123
Page 1: ...FrameSaver FLEX 9123 User s Guide Document No 9123 A2 GB20 20 August 2001 ...
Page 10: ...Contents viii August 2001 9123 A2 GB20 20 ...
Page 24: ...1 About the FrameSaver FLEX 9123 1 10 August 2001 9123 A2 GB20 20 ...
Page 34: ...2 User Interface and Basic Operation 2 10 August 2001 9123 A2 GB20 20 ...
Page 98: ...3 Configuration 3 64 August 2001 9123 A2 GB20 20 ...
Page 212: ...8 Setting Up NetScout Manager Plus for FrameSaver Devices 8 18 August 2001 9123 A2 GB20 20 ...
Page 228: ...A Menu Hierarchy A 6 August 2001 9123 A2 GB20 20 ...
Page 258: ...B SNMP MIBs and Traps and RMON Alarm Defaults B 30 August 2001 9123 A2 GB20 20 ...
Page 266: ...C Connectors Cables and Pin Assignments C 8 August 2001 9123 A2 GB20 20 ...