15
Connecting to the Network
Now that the FrameSaver unit is set up, the unit can be connected to the network.
Procedure
1.
Insert the 8-pin connector of the RJ48C network cable into the network interface.
2.
Insert the other end of the cable into the RJ48C modular jack.
NOTE:
After connecting the network cable, wait about a minute to allow
Auto-Configuration a chance to discover the operating rate and the DLCIs.
3.
Verify that the Network signal (SIG) LED is green, and that the Network
out-of-frame (OOF) and alarm (ALM) LEDs are off. If so, the network interface is set
up correctly and is operational. If not, make sure both ends of the network cable are
properly seated.
4.
Check Health and Status messages in the left column of the System and Test
Status screen.
Main Menu
→
Status
→
System and Test Status
Verify that LMI is up. If
LMI Down, Network
appears for more than three
minutes, or any other network-related status message appears, refer to the status
information in the
FrameSaver SLV Operations Guide (9000-A2-GB33)
for possible
reasons and resolutions.