Speed

On the ENE2020-P (only), switches 1 and 2 control the port speed.

The E1 lines each have 31 channels continually running at 64 kbps for a collective 
bandwidth of 1,984 kbps. The timeslot configuration determines how many of the 
channels for each port will actually receive data. Ports configured to operate as 
fractional E1 lines require contiguous timeslots as indicated in the table below.

Port 1 configuration switches 1 and 2 on the ENE2020-P work together to provide four 
timeslot/bandwidth options for the Port 1 E1 link. Port 2 configuration switches 1 and 2 
on the ENE2020-P provide the timeslot/bandwidth options for the Port 2 E1 link. 

The ENE2020-S determines timeslot and bandwidth configurations for the two E1 links 
via communication with its partner E1 provider unit.

Frame Type

Switch 3 sets the Frame Type for Port 1 on both the ENE2020-P and the ENE2020-S. 
Switch 3 controls the frame type of both E1 ports (Port 1 and Port 2); frame type for the 
two ports cannot be configured independently.

Frame type is the E1 data encapsulation method. A frame consists of 248 bits (8-bit 
samples of each of the 31 E1 data channels plus a synchronization bit) transmitted at a 
rate of 8,000 frames per second (1,984 kbps) across the E1 line. The ENE2020 can be 
configured to use Cyclic Redundancy Check (CRC) to detect line errors and scrutinize 
data integrity across the E1 line by appending a hexidecimal checksum (calculated from 
the previous E1 frame contents) to the end of each E1 frame. The remote modem then 
makes a similar calculation upon receipt of each E1 frame and compares it to the 
checksum of the ensuing E1 frame.  

Table 2. Speed Settings Using Switches 1 and 2

Switch 1

Switch 2

Timeslots

Bandwidth (kbps)

Down

Down

1–31

1,984

Up

Down

1–24

1,536

Down

Up

1–16

1,024

Up

Up

1–8

512

Table 3. Frame Type Settings Using Switch 3

Switch 3

Frame Type

Down

Cyclic Redundancy Check

Up

No Cyclic Redundancy Check

Summary of Contents for ENE2020-P

Page 1: ...to the software and or firmware individually or collectively the Software incorporated into the Paradyne product the Product purchased by you and any derivatives obtained ONCE YOU HAVE READ THIS LICENSE AGREEMENT AND AGREE TO ITS TERMS YOU MAY USE THE SOFTWARE AND OR FIRMWARE INCORPORATED INTO THE PARADYNE PRODUCT BY USING THE PARADYNE PRODUCT YOU SHOW YOUR ACCEPTANCE OF THE TERMS OF THIS LICENSE ...

Page 2: ... other warranty whatsoever with respect to the Product purchased by you THIS AGREEMENT EXPRESSLY EXCLUDES ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED OR ORAL OR WRITTEN INCLUDING WITHOUT LIMITATION a Any warranty that the Software is error free will operate uninterrupted in your operating environment or is compatible with any equipment or software configurations and b ANY AND ALL IMPLIED WARRA...

Page 3: ...nuals To order a paper copy of a Paradyne document or to speak with a sales representative please call 1 727 530 2000 Warranty Sales Service and Training Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations o...

Page 4: ... the Ethernet link will remain disabled as indicated by no illumination of the Ethernet 100 Act and Lnk LEDs until at least one of the two E1 connections has been established 10 100 Connection Port 1 Port 1 Config 04 17581 Power Adapter 5V DC Port 2 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 Port 2 Config T1 or E1 04 17580 Port 2 E1 Connection Power Lnk 100 Act Lnk 10 100 Ethernet Connection E1 Network Exten...

Page 5: ...ame type is determined by the Port 1 frame type configuration Frame Type Not used Port 2 frame type is determined by the Port 1 frame type configuration 4 Line Code Not used Port 2 line code is determined by the Port 1 line code configuration Line Code Not used Port 2 line code is determined by the Port 1 line code configuration 5 Not used Not used Not used Not used 6 Not used Not used Not used No...

Page 6: ...0 P and the ENE2020 S Switch 3 controls the frame type of both E1 ports Port 1 and Port 2 frame type for the two ports cannot be configured independently Frame type is the E1 data encapsulation method A frame consists of 248 bits 8 bit samples of each of the 31 E1 data channels plus a synchronization bit transmitted at a rate of 8 000 frames per second 1 984 kbps across the E1 line The ENE2020 can...

Page 7: ...itive and negative pulses Although AMI links typically encounter long strings of zeros which can potentially cause loss of synchronization between units the ENE2020 meets the European minimum ones density requirement internally such that even with AMI loss of synchronization is prevented between the ENE2020 and remote E1 equipment just as it is with HDB3 Timing Switch 7 sets the timing for the ENE...

Page 8: ... Port 2 on the back of the ENE2020 The order of connection is not important 2 Verify both connections the Port 1 and Port 2 Lnk LEDs on the front of the ENE2020 will pulse green to indicate the connections are established and operational Single E1 Connection A single line connection can be established between an ENE2020 S and any Paradyne E1 provider unit regardless of loop bonding capability Like...

Page 9: ...Duplex Procedure 1 Plug the Ethernet cable into the 10 100 Ethernet Port on the back of the ENE2020 2 Verify the connection solid green illumination of the 10 100 Ethernet Connection Lnk Link LED on the front of the ENE2020 indicates a connection has been established If the Ethernet Lnk LED is illuminated but not the Ethernet 100 LED then a 10 Mbps connection has been established If the Ethernet L...

Page 10: ... connection exists but there is indication of a problem with the E1 line No Illumination Loss of Synchronization LOS The incoming connection to the unit has been lost no data is being received If the outgoing connection from the unit has also been lost then the unit s partner ENE2020 will have LOS as well E1 Connections Alm Port 1 and Port 2 No Illumination E1 is operational An established E1 link...

Page 11: ...ction Act Pulsing Amber Standard operation Traffic is flowing without any problems Solid Amber Heavy traffic No Illumination No activity Either there is no Ethernet link or a link exists but there is no activity 10 100 Ethernet Connection Lnk Solid Green Ethernet connection is established If the Ethernet Lnk LED is illuminated but not the Ethernet 100 LED then a 10 Mbps connection has been establi...

Page 12: ...3 6 7 and 8 Ethernet RJ45 Pin Assignments Table 7 E1 RJ45 Pin Assignments Pin Function Pin 1 Rx Ring Pin 2 Rx Tip Pin 3 not used Pin 4 Tx Ring Pin 5 Tx Tip Pin 6 not used Pin 7 not used Pin 8 not used Table 8 Ethernet RJ45 Pin Assignments Pin Function Pin 1 Rx Pin 2 Rx Pin 3 Tx Pin 4 not used Pin 5 not used Pin 6 Tx Pin 7 not used Pin 8 not used ...

Page 13: ...this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense The authority to operate this equipment is conditioned by the requirements that no modifications will be made to the equipment unless the changes or modifications are expressly approved by Paradyne Corporation If the equipment includes ...

Page 14: ...ts installed in separate buildings are interconnected the voltage potential may cause a hazardous condition Consult a qualified electrical consultant to determine whether or not this phenomenon exists and if necessary implement corrective action prior to interconnecting the products 7 Input power to this product must be provided by one of the following 1 a UL Listed CSA certified power source with...

Page 15: ...15 ...

Page 16: ...16 ENE2 A2 GN10 10 ENE2 A2 GN10 10 ...

Reviews: