4. AT Command Set and S-Registers
4-39
3830-A2-GB91-30
August 1998
Table 4-3
(10 of 20)
Model 3830 S-Registers
S48
Leased Line Carrier On Level
Determines if the modem disconnects if the carrier signal on leased lines
falls below –26 dBm or –43 dBm.
Register has the following values:
0 = –43 dBm
1 = –26 dBm
Factory setting is –43 dBm.
S49
Transmit Buffer Disconnect Delay
Determines the maximum amount of time the modem can continue to
send data in its Transmit Buffer to the remote modem after it is
commanded by the DTE to disconnect.
Register has the following values:
0 = Disable (Immediate disconnect)
1 = 1 second
2 = 2 seconds
D
D
D
D
255 = 255 seconds
Factory default is 10 seconds.
S51
DTE Remote Loopback (CT140)
Determines if the modem performs a remote digital loopback if it receives
a CT140 signal from the DTE.
Register has the following values:
0 = Disable
1 = Enable
Factory setting is Disable.
Summary of Contents for COMSPHERE 3830
Page 1: ...COMSPHERE 3800 SERIES MODEMS MODEL 3830 USER S GUIDE Document No 3830 A2 GB91 30 August 1998 ...
Page 6: ...COMSPHERE 3800 Series Modems Model 3830 E August 1998 3830 A2 GB91 30 Notices ...
Page 22: ...COMSPHERE 3800 Series Modems Model 3830 1 6 August 1998 3830 A2 GB91 30 ...
Page 86: ...COMSPHERE 3800 Series Modems Model 3830 4 50 August 1998 3830 A2 GB91 30 ...
Page 104: ...COMSPHERE 3800 Series Modems Model 3830 C 6 August 1998 3830 A2 GB91 30 ...
Page 114: ...COMSPHERE 3800 Series Modems Model 3830 D 10 August 1998 3830 A2 GB91 30 ...
Page 126: ...COMSPHERE 3800 Series Modems Model 3830 Glossary 12 August 1998 3830 A2 GB91 30 ...