background image

 21

AT COMMANDS (continued)

\N1

Direct Mode.  Modem does not use error
control; DTE rate and VF rate must be
the same.

\N2

MNP or Disc.  Modem disconnects if it
does not connect in MNP mode.

\N3

MNP or Buffer.  Modem connects in
Buffer mode if it does not connect in MNP
mode.

\N4

V.42/MNP or Disc.  Modem disconnects if
it does not connect in V.42 or MNP mode.

\N5

V.42/MNP or Buffer.  Modem connects
in Buffer mode if it does not connect
in V.42 or MNP mode.

\N6

LAPM or disconnect.

\N7

LAPM or buffer.

\Qn

Flow Control of DTE

\Q0, \Q5, \Q6

Disables flow control of DTE.

\Q1, \Q4

Enables XON/XOFF flow control.

\Q2, \Q3

Modem raises and lowers CTS to start
and stop flow control.

\Qn

Flow Control of Modem

\Q0, \Q2, \Q4

Disables flow control of modem.

\Q1, \Q5

Enables XON/XOFF flow control.

\Q3, \Q6

Modem starts and stops flow control
based upon state of DTE’s RTS signal.

\Tn

No Data Disconnect Timer

\T0

Disables no data disconnect timer.

\Tn

Sets no data disconnect timer to a value
from 1 minute to 255 minutes.

\Xn

XON/XOFF Passthrough

\X0

Disables transmission of flow control
characters to remote modem.

\X1

Enables transmission of flow control
characters to remote modem. 

%A

n

Sets error control fallback character 

n to

an ASCII value from 0 to 127.

%B

n

Sets data rate to 

n (300 to 19200). 

%Cn

MNP 5 Data Compression

%C0

Disables MNP5 data compression.

%C1

Enables MNP5 data compression.

%R

n

Sets DTE rate to 

n (300 to 115200). 

Hn

V.42 bis Data Compression

H0

Disables V.42bis data compression.

H1

Enables V.42bis data compression for
transmit only.

H2

Enables V.42bis data compression for
receive only.

H3

Enables V.42bis data compression 
in both the transmit and receive 
directions.

RESULT CODES

Numbers(1) Numbers(2) Words
 

  0

  0

OK

 

  1

  1

CONNECT

 

  2

  2

RING

  

  3

  3

NO CARRIER

  

  4

  4

ERROR

Result Codes 5–14, 16, 19 are enabled with the X1,
X2, X3, and X4 commands.
  

  5

  5

CONNECT 1200

 

  6

  6

NO DIALTONE

  

  7

  7

BUSY

 

  8

  8

NO ANSWER

10

10

CONNECT 2400

11

11

CONNECT 4800

12

12

CONNECT 9600

13

16

CONNECT 12000

14

13

CONNECT 14400

15

14

CONNECT 19200

16

15

CONNECT 7200

17

17

CONNECT 16800

19

19

CONNECT 300

Result Codes 20–27 are enabled with the X5
command (EC suffix) or the X6 command (V.42 or
MNP suffix).

20

10

CONNECT 2400/EC

21

11

CONNECT 4800/EC

22

12

CONNECT 9600/EC

23

16

CONNECT 12000/EC

24

13

CONNECT 14400/EC

25

17

CONNECT 16800/EC

26

15

CONNECT 7200/EC

27

  5

CONNECT 1200/EC

29

14

CONNECT 19200/EC

Result Codes 15, 28–34 are enabled with the X7
command (DTE rate suffix).

28

28

CONNECT 38400

30

30

CONNECT 57600

32

32

CONNECT 76800

34

34

CONNECT 115200

DIAL COMMAND MODIFIERS

T

Tone Dial (DTMF)

P

Pulse Dial

,

Pause

W

Wait for Dial Tone

R

Reverse Dial

@

Quiet Answer

!

Hook Flash

;

Return to Command Mode

Summary of Contents for COMSPHERE 3810

Page 1: ...COMSPHERE 3800 SERIES MODEMS MODELS 3810 3811 AND 3820 QUICK REFERENCE Document No 3810 A2 GL10 00 ...

Page 2: ... and issued as a new release to this manual Warranty Sales and Service Information Contact your local sales representative service representative or distributor directly for any help needed For additional information concerning warranty sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods Via the Inte...

Page 3: ...stalling the Documentation The user documentation may be in a compressed format Before installation please read the aboutdoc txt file on the diskette for appropriate installation instructions Using the Adobe Acrobat Reader For best viewing 1 Use your operating system s file manager to copy the PDF file to your hard disk then use the Adobe Acrobat Reader to open the file from your hard disk This is...

Page 4: ...odels 3810 and 3820 Installation 496 13096 02 EIA 232 D INTERFACE NMS DIAL LEASED 3820 PHONE LEASED 3810 AC POWER IN ON OFF STATUS INDICATORS AC TRANSFORMER LCD AND KEYPAD DIAGNOSTIC CONTROL PANEL SPEAKER ...

Page 5: ... Insert the other end of the modular cord into the telephone Dial Network Management System Connection For Model 3810 and 3820 modems use the following procedures to connect the modem to the network management system interface 1 Insert the subminiature 4 conductor modular plug of the 3600 Hubbing Device into the jack labeled NMS 2 Connect the 3600 Hubbing Device to the network management system Re...

Page 6: ...res to connect a Model 3810 to the 2 wire or 4 wire leased line network interface 1 Insert the 8 position 8 conductor modular plug into the jack labeled PHONE LEASED 3810 2 Insert the other end of the modular cord into the leased line network interface PHONE DIAL NMS DTE PWR 0 1 LEASED 3820 LEASED 3810 98 13070 02 8 POSITION 8 CONDUCTOR PLUG FOR LEASED LINE NETWORK OPERATION CONNECTS WITH JM8 TYPE...

Page 7: ...e jack labeled DIAL LEASED 3820 2 Insert the other end of the modular cord into the network interface PHONE DIAL NMS DTE PWR 0 1 LEASED 3820 LEASED 3810 98 13071 02 6 POSITION 4 CONDUCTOR PLUG FOR TELEPHONE SET 6 POSITION 4 CONDUCTOR PLUG FOR PERMISSIVE DIAL NETWORK OPERATION CONNECTS WITH RJ11C TYPE JACK 2 WIRE LEASED LINE NETWORK OPERATION CONNECTS WITH 6 POSITION CENTER PAIR LEASED JACK OR ...

Page 8: ...le to the DTE Use a small screwdriver to fasten the cable to the DTE To ensure compliance with FCC Part 15 Regulations a ferrite choke must be installed on the EIA 232 D interface cable 1 Open the ferrite choke and place it around the DTE cable as close as possible to the connector attached to the modem 2 Close the two halves around the cable and snap the ferrite choke shut pressing down on the pl...

Page 9: ...05 106 107 108 109 Pwr Alrm Test Dial RI Busy Serv SQ Status Front Panel 3811 142 125 Spkr FACEPLATE EIA 232 V 24 EDGE CARD CONNECTOR RS 366A V 25 EDGE CARD CONNECTOR EIA 232 V 24 CONNECTOR RS 366A V 25 CONNECTOR V 35 3600 3500 RS366A V 25 3800 EIA232 V 24 REAR CONNECTOR PLATE ...

Page 10: ...network management applications A Shared Diagnostic Unit SDU required for network management applications Model 3811 Installation The Model 3811 is designed for installation in a COMSPHERE 3000 Series Carrier which supplies operating power and the dial and or leased line network connections For correct power DTE dial line leased line NIM and network management cabling information refer to the COMS...

Page 11: ...lide the modem into the slot aligning the modem with the rear connector plate until the backplane connector and DTE connector seat firmly into the back of the carrier The faceplate latch automatically closes as you push the modem into the carrier To lock the modem into the carrier press the faceplate latch until a click is heard 3 If the carrier is ON the Power LED on the faceplate of the 3811 lig...

Page 12: ...t appears on the LCD 5 Press the Select key to place the SDCP in direct communication with the selected modem The LCD displays the Top Level menu for the selected modem In addition the Front Panel LED on the modem s faceplate and the OK LED on the SDCP light 6 Once you have determined that the modem is installed properly and completed its power up self test rotate the circuit pack lock until it co...

Page 13: ...ter liquid crystal display LCD a keypad speaker grill and status indicators KEYPAD HIDDEN CHOICE INDICATOR STATUS INDICATORS SPEAKER I d l e 1 9 2 C a l l _ S e t u p PWR ALRM CTS TXD LSD RXD TEST RATE 105 106 103 109 108 142 COMSPHERE 3810 F1 F2 F3 SQ RTS DTR 104 DIAG CTS TXD LSD RXD 105 106 103 109 COMSPHERE 3820 RTS 104 SQ ...

Page 14: ...m the current display Moves cursor or display to the left or right Returns display to Top Level menu Selects item displayed directly above the key F1 F2 F3 and Direction and Function keys provide operator control Hidden Choice Indicators Indicates more LCD selections are available to the left or right of what is currently displayed on the LCD Indicates more configuration options are available belo...

Page 15: ...vailable Select Configure from the Top Level menu F1 Idle 19 2 Test Configure F2 F3 Scroll to the area you wish to load F1 Ld EditArea frm Factory F2 F3 2 Select Edit to choose the set of configuration options to be edited DTE Interface DTE Dialer Line Dialer Dial Line Leased Line V 42 MNP Buffer Tests Misc or Security F1 Edit StrapGroup Test Misc F2 F3 3 When the new configuration is completed Sa...

Page 16: ... BusyTone Detect Pause Time NoAnswer Timout Fast Disconnect Line Crnt Disc Long Space Disc No Carrier Disc No Data Disc Auto Make Busy MakeBusyViaDTR DTR Auto Redial Dial_Line Dial Line Rate 19200 V32t 16800 V32t 14400 V32b 12000 V32b 9600 V32b 7200 V32b 4800 V32b 2400 V22bis 1200 V22 1200 212A 0 300 V21 0 300 103J V32bisAutomode V32bisAutorate Dial TX Level V22b Guard Tone V32bis Train FallFwdDel...

Page 17: ...C Negotiat Bfr EC Fallbck Char Flw Cntl of DTE Flw Cntl of Mdm XON XOFF Psthru Mdm Mdm FlowCtl Break Buffr Ctl Send Break Cntl Tx Buff Disc Delay Rx Buff Disc Delay Max Frame Size Cellular Enhance Tests DTE RL CT140 DTE LL CT141 Test Timeout Rcv Remote Loop V54Address V54 Device Type Misc StrapsWhenDisc Speaker Control Speaker Volume Access frm Remt RemAccssPasswrd Dir 1_Callback NetMngmtAddress N...

Page 18: ...e_Line or DiscServLine Download Code Secondary Prim data blckd ExitRem appears instead of Remote when using Remote Mode Security Set_Access_Ctrl Admin Password Reset_Security EditPassWdTable Set_Answer_Sec Set_Orig_Secur Set_Admin_PsWd 98 14436c 03 from previous page ...

Page 19: ...nswer 3 UNIX Dial 4 Sync Leased Originate 5 Cellular Mobile Valid only if ETC is installed 6 Cellular PSTN Valid only if ETC is installed where n is one of the following configuration areas 0 Active Saved 1 Customer 1 2 Customer 2 Loading Configuration Areas to Active Operating Use the ATZn command to load stored configurations from Active Saved Customer 1 or Customer 2 configuration areas to Acti...

Page 20: ...t codes Refer to Result Codes section Q1 Disables result codes Q2 Enables originate modem to send result codes to the DTE Required for most UNIX applications Sr Displays value of S Register where r is the register number Sr n Change S Register Changes the contents of the S Register where r is the register number and n is the assigned value T Enables Tone Dial mode Vn Result Code Format V0 Displays...

Page 21: ...ation options into Active Operating configuration area F4 Loads Sync Leased Originate Mode factory configuration options into Active Operating configuration area F5 Cellular Mobile Valid only if ETC is installed AT COMMANDS continued F6 Cellular PSTN Valid only if ETC is installed Gn V 22bis Guard Tone G0 Disables guard tone G1 Sets guard tone to 550 Hz G2 Sets guard tone to 1800 Hz In Dial Transm...

Page 22: ...rovides internal clock source for synchronous data Pin 15 X1 Modem uses external source Pin 24 for clock for synchronous data AT COMMANDS continued X2 Modem uses received signal as clock source for synchronous data Zn x Modem stores telephone number x and any dial modifiers in directory location n 1 10 For example the command AT Z1 555 1234 stores the number 5551234 in directory location 1 To clea...

Page 23: ...ets data rate to n 300 to 19200 Cn MNP 5 Data Compression C0 Disables MNP5 data compression C1 Enables MNP5 data compression Rn Sets DTE rate to n 300 to 115200 Hn V 42 bis Data Compression H0 Disables V 42bis data compression H1 Enables V 42bis data compression for transmit only H2 Enables V 42bis data compression for receive only H3 Enables V 42bis data compression in both the transmit and recei...

Page 24: ...0 S38 DTR Cont Repeat 0 0 Disable 1 Enable S39 Receive Buffer Disconnect Delay 0 0 Disable or 1 255 seconds S40 Auto Make Busy 0 0 Disable 1 Enable S41 Dial Line Rate 21 1 14400 V 32bis 2 12000 V 32bis 3 9600 V 32bis 4 7200 V 32bis 5 4800 V 32bis 6 2400 V 22bis 7 1200 V 22 8 1200 212A 10 0 300 V 21 11 0 300 103J 20 19200 V 32terbo 21 16800 V 32terbo S43 V 32bis Train 0 0 Long 1 Short S44 Leased Li...

Page 25: ...ress Only S67 Directory Location 1 Callback 0 0 Disable 1 Enable S69 Make Busy Via DTR 0 0 Disable 1 Enable S74 Network Position 0 0 Tributary 1 Control S75 Network Management Address 255 0 255 001 256 S76 V 32bis Dial Autorate 0 0 Enable 1 Disable 2 Start at 4800 bps 3 Start at 9600 bps S77 DTR Alarm Reporting 0 0 Disable 1 Enable S78 V 32bis Dial Automode 0 0 Enable 1 Disable 2 System85 S80 No D...

Reviews: