Select Factory Configuration
Options

After the modem passes the power-up self-test,

configure it for operation using one of the factory preset
configurations.

The 3811Plus modem has several factory preset

templates that contain the proper configuration options
(straps) for different environments. Modems are shipped
from the factory with the Async Dial default configuration
options stored in memory. To prepare the modem for Sync
Dial, Sync Leased, UNIX Dial, Cellular (Mobile), or
Cellular (PSTN), you must change the factory setting,
using either the SDCP or the AT command &Fn, as
described in the following sections.

The Cellular (Mobile) and Cellular (PSTN) settings

(and the analogous AT commands &F5 and &F6) are
available only if Enhanced Throughput Cellular (ETC

)

is installed.

Configuring a Modem Using the SDCP

To change a factory template from the Async Dial

preset configuration using the SDCP, perform the
following steps.

Procedure

1. Press the 

Select

 key on the SDCP. Use the

function keys to enter the carrier number and slot
number of the modem to be configured. Press the

Select

 key again. The Front Panel LED of the

selected modem lights up.

2. Press the  

  key until Configure comes into

view.

F1

Idle : 28.8
Test             Configure

F2

F3

3. Press the function key below Configure to select

the Configure branch.

The LCD now displays Ld EditArea frm.

4. Press the  

  key until Factory comes into view,

then press the F1 key to display the factory preset
configurations.

5. Press the  

  key until the appropriate factory

preset appears on the LCD, and press the
corresponding function key to select your choice.

If you select Sync Leased, a new prompt asks you
to select Answer Mode (F1) or Originate Mode
(F3). Press the appropriate key.

6. Choose Function now appears and displays the

Edit and Save functions.

7. Press the F3 key (Save).

The LCD displays Sav EditArea to.

8. The Active (Saved), Customer 1, and Customer 2

configuration areas are nonvolatile memory
locations. Active (Saved) contains the most
recently saved changes to any configuration
options. In the event of power loss, the modem
retrieves these configuration options.

Press the F1 key to select Active (Saved). The
LCD displays Command Complete.

9. The modem is now configured with the selected

factory template. Press the  

  key to return to

the Top-Level menu.

Configuring a Modem Using AT Commands

When using AT commands, the following criteria must

be met:

Make sure the asynchronous DTE’s communication
software is configured for 10-bit character format
(including the start bit); for example, 8 data bits, no
parity, and 1 stop bit.

Make sure the DTE (RS-232D) cable is attached to
the DTE connector on the rear of the
COMSPHERE 3000 Series Carrier, and the correct
serial communications port on the asynchronous
DTE.

On initial power-up, the modem is in Command
mode. To verify that the modem is connected and
functioning properly, enter the following:

TYPE: AT

PRESS: Return (Enter)

The screen displays OK.

Summary of Contents for COMSPHERE 3800PLUS

Page 1: ...es may be provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibility of the customer 4 When installed in th...

Page 2: ...corporation commission for information 9 The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone...

Page 3: ...chband circuit and 2 All that other apparatus shall comprise only i apparatus approved for the purpose of connection between the apparatus and a speechband circuit and ii cable or wiring complying wit...

Page 4: ...our automated call system to receive current information via fax or to speak with a company representative Within the U S A call 1 800 870 2221 From outside the U S A call 727 530 2340 Installation C...

Page 5: ...SD 103 104 105 106 107 108 109 Pwr Alrm Test Dial RI Busy Serv SQ Status Front Panel 3811Plus 142 125 Spkr Faceplate EIA232 V 24 Edge Card Connector EIA232 V 24 Connector Unused V 35 3600 3500 RS366A...

Page 6: ...ot position as that intended for the modem 496 14906 V 35 3600 3500 RS366A V 25 3800 EIA232 V 24 25 Pin DTE Connectors P21 Loosely fasten the plate This allows for slight adjustments later when instal...

Page 7: ...em Perform the following steps Select SDU 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 COMSPHERE 3000 Select Key Status Indicators Carrier Slots 1 16 F1 F2 F3 OK Alarm BckUp Test EC Keypad LCD Display 496 1...

Page 8: ...e key until Factory comes into view then press the F1 key to display the factory preset configurations 5 Press the key until the appropriate factory preset appears on the LCD and press the correspondi...

Page 9: ...nds F5 and F6 are available only if Enhanced Throughput Cellular ETC is installed Menu Structure The menu tree accessible from the SDCP contains the following branches Call Setup Used to dial disconne...

Page 10: ...ype DialTone Detect Blind Dial Paus BusyTone Detect Pause Time NoAnswer Timout Fast Disconnect Long Space Disc No Carrier Disc No Data Disc NoDataDiscTrig Auto Make Busy MakeBusyViaDTR DTR Auto Redial...

Page 11: ..._Msgs NMS DTR Alarm NetworkPosition CellulrRJ11Adpt Security EntryWait_Time VF_Prompt_Type DTE_PW_Tries DTE_PW_TermChar DTE_PW_BkSpChar Get_User_ID NMS_Reporting Answer_Secur Originate_Secur 98 14528b...

Page 12: ...pears instead of Remote when using Remote Mode Does not appear in Remote Mode Rem_Digital_Loop Loc_Digital_Loop and Pattern appear if the secondary channel is used Security Set_Access_Ctrl Admin Passw...

Reviews: