background image

COMSPHERE 3600 Data Service Units

ii

December 1996

3610-A2-GB43-50

Product-Related Documents

The following table lists 3600-related documentation.

COMSPHERE 3600 Series Product-Related Documentation

Document Name

Document

Number

Description

COMSPHERE 3600 Series Data
Service Units, Models 3610 and
3611, User’s Guide

3610-A2-GB46

User’s Guide. Ships with all standalone 3610 DSUs. Provides
descriptions of features, installation instructions, front panel
operation, configuration options and worksheets, troubleshooting,
messages, and specifications.

COMSPHERE 3600 Series Data
Service Units, Models 3610 and
3611, Time Division Multiplexer,
Multichannel Multipoint, and
Digital Bridge Options
Supplement

3610-A2-GB48

Supplement to the User’s Guide. Ships with all standalone
3610 DSUs with TDM, MCMP, or Digital Bridge options or
upgrades. Provides descriptions of TDM, MCMP, and Digital Bridge
features, installation instructions, front panel operation,
configuration options and worksheets, troubleshooting, messages,
and specifications.

COMSPHERE 3600 Series Data
Service Units, Models 3610 and
3611, Dial Backup Module
Options Supplement

3610-A2-GB49

Supplement to the User’s Guide. Ships with all standalone
3610 DSUs with Dial Backup Modules or upgrades. Provides
descriptions of DBMs, features, installation instructions, front panel
operation, configuration options and worksheets, troubleshooting,
messages, and specifications.

COMSPHERE 3600 Series Data
Service Units, Models 3610 and
3611, Technical Reference
Manual

3610-A2-GH30

Orderable. Provides detailed information on the DSU, DBM, SNA
Diagnostic Interface, TDM, MCMP, and Digital Bridge features,
specifications, configuration scenarios, async terminal operation,
pin assignments, NMS operations, messages, and an equipment
list.

COMSPHERE 3600 DBM Option
Installation Instructions

3610-A2-GZ52

Ships with field-installable dial backup upgrades. Contains
installation procedures for all Model 3610 and 3611 DBM types.

COMSPHERE 3000 Series
Carrier, Installation Manual

3000-A2-GA31

Ships with every carrier. Contains installation procedures for the
carrier and its components, options, and operation.

COMSPHERE – 48 Vdc Central
Office Power Unit, Installation
Guide

3000-A2-GB41

Ships with every – 48 Vdc power unit. Includes descriptions of
features, installation instructions, troubleshooting, specifications,
and an equipment list.

COMSPHERE 3600 Series Data
Services Units, Models 3610 and
3611, Secondary Channel
Applications Supplement

3610-A2-GB42

Orderable. Provides details on DSUs equipped with the Secondary
Channel option. Provides descriptions of features, DSU operation,
configuration examples, worksheets, and an equipment list.

COMSPHERE 6800 Series
Network Management System,
Communications Products
Support, Command Reference
Manual

6800-A2-GB31

Ships with software. Provides descriptions of device commands for
interaction between 6800 Series NMS and other product lines.

COMSPHERE 6700 Series
Network Management System,
User’s Guide

6700-A2-GY31

Ships with software and is orderable. Provides descriptions of NMS
features, installation instructions, configuration setup, display and
statistics options, reports generation, online help conventions, and
input forms.

Summary of Contents for COMSPHERE 3610

Page 1: ...COMSPHERE 3600 SERIES DATA SERVICE UNITS MODELS 3610 AND 3611 DOCUMENTATION REPLACEMENT Document No 3610 A2 GB43 50 Feature No 3600 G3 002 December 1996...

Page 2: ...ne com Via Telephone Call our automated call system to receive current information via fax or to speak with a company representative Within the U S A call 1 800 870 2221 International call 727 530 234...

Page 3: ...fied service personnel 6 General purpose cables are provided with this product Special cables which may be required by the regulatory inspection authority for the installation site are the responsibil...

Page 4: ...COMSPHERE 3600 Series Data Service Units C December 1996 3610 A2 GB43 50 Notices...

Page 5: ...5 Call your local telephone company to ascertain the maximum REN for your calling area If your Model 3610 or 3611 DSU with DBM causes harm to the telephone network the telephone company may discontin...

Page 6: ...lation Requirements DBM Type USOC Jack Standalone USOC Jack Carrier Mounted Canadian Jack Standalone Canadian Jack Carrier Mounted 12 0 or 14 4 kbps V 32bis DBM RJ11C Permissive RJ45C Programmable RJ2...

Page 7: ...telephone lines and internal metallic water pipe system if present are connected together for protection This precaution may be particularly important in rural areas CAUTION Users should not attempt...

Page 8: ...Modules DBMs Time Division Multiplexer TDM Multichannel Multipoint MCMP and the digital bridge options Chapter 2 describes electrical connection of the Model 3610 DSU as well as Digital Data Service D...

Page 9: ...Manual 3610 A2 GH30 Orderable Provides detailed information on the DSU DBM SNA Diagnostic Interface TDM MCMP and Digital Bridge features specifications configuration scenarios async terminal operatio...

Page 10: ...ble 1 1 1 of 3 General COMSPHERE 3600 Series Technical Specifications Specifications Criteria AC POWER FUSE Model 3610 3611 DSU 3000 Series Carrier No accessible fuse 4 amp fuse Paradyne part number 1...

Page 11: ...CCITT V 24 ISO 2110 ITU CCITT V 35 ISO 2593 A modular DSU V 35 interconnect cable is required to use the V 35 connector The cable provides an interface between the DSU s 25 pin D type connector and t...

Page 12: ...NS 3610 DSU Height Width Depth 3611 DSU non modular or modular Height Width thickness Depth Rear Connector Plate 2 port Height Width Depth 25 Pin V 35 Interface 3000 Series Carrier Height Width Depth...

Page 13: ...610 DSU 3611 DSU Requires 3600 Hubbing Device which provides two 8 pin modular jacks Via the SDU in the COMSPHERE 3000 Series Carrier or DC OUT via NMS adapter cable for a tributary in the carrier NET...

Page 14: ...ICATION Diagnostic interfaces for the Model 3610 DSU NETWORK MANAGEMENT INTERFACES NMS Two 8 pin modular jacks Note that the 3600 Hubbing Device has a 6 inch attached cable that terminates in a 4 pin...

Page 15: ...4 8 7 2 9 6 12 14 4 kbps DBM COMPATIBILITY If Call Setup is set for Callback or Password security then the device is compatible with a 3600 Series V 32 DBM only If Call Setup is set for Alarm or None...

Page 16: ...ter Receiver Compromise equalizer Automatic adaptive equalizer COMMUNICATION LINE 2 wire analog PSTN line DATA RATES 2 4 4 8 7 2 9 6 12 14 4 16 8 19 2 21 6 24 26 4 and 28 8 kbps DBM COMPATIBILITY If C...

Page 17: ...COMMUNICATION LINE A dedicated 2 wire access or a local exchange carrier 2 wire switched access DATA RATES 56 kbps Note that 2 wire Switched 56 DBM or DBM D use proprietary rate adaption to support da...

Page 18: ...local exchange carrier 4 wire switched access DATA RATES 56 kbps Note that 4 wire Switched 56 DBM or DBM S use proprietary rate adaption to support data rates of less than 56 kbps DBM COMPATIBILITY If...

Page 19: ...equalizer with echo cancellation COMMUNICATION LINE 2 wire BRI ISDN line DATA RATES 56 and 64 kbps Note that ISDN DBM or DBM I use proprietary rate adaption to support data rates of less than 64 kbps...

Page 20: ...onnector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater Provides five additional 25 pin D subminiature con...

Page 21: ...additional 25 pin D subminiature connector for a total of two EIA 232 or V 35 interfaces that can be set independently of each other when you have DSU firmware Release 6 28 or greater Provides five a...

Page 22: ...independently of each other when you have DSU firmware Release 6 28 or greater Provides five additional 25 pin D subminiature connectors for a total of six EIA 232 or V 35 interfaces that can be set...

Page 23: ...within 6 feet that is protected by a circuit breaker Label the circuit breaker that protects the ac outlet and ensure that the circuit breaker is set to ON Your installation site is clean well lit ven...

Page 24: ...or by using an adapter Prior to installation use an outlet tester or voltmeter to check the ac receptacle for earth ground If the power source does not provide a ground connection consult an electrici...

Page 25: ...lights Alrm indicator goes off Health and Status screen no longer displays a No Signal message If connecting the DSU to a LADS network there are distance limitations that govern the use of DSUs on th...

Page 26: ...e switched 56 kbps network connection 495 14860 Switched 56 kbps Network Connection Backup POW ER LINE BACKUP CC DC V 35 SJA56 or SJA48 Wall Jack ISDN DBM Network Connection The 2 wire ISDN DBM has an...