
Installing the Model 3550 DSU
2-3
3550-A2-GB20-40
July 1999
496-14457-01
SWITCH 1
HINGE TAB
LOCATIONS
FRONT BEZEL
COMSPHERE
3550
SNAP
TABS
Figure 2-1. Model 3550 Hardware Switch Location (shown without a TDM/Flex)
Table 2-1
Model 3550 DSU Switch Settings
Switch Position
Switch Setting
Function
S1-1
ON
(default)
Permissive V.32 DBM transmit output level of –9 dBm
S1-1
Off
Programmable V.32 DBM transmit level between –12 dBm and 0 dBm
ON
Frame ground (FG) connected to signal ground (SG)
S1-2
Off
(default)
FG connected to SG through 100 ohm resistor
ON is to the rear as you face the front of the DSU.
Off is to the front.
Summary of Contents for Comsphere 3551
Page 4: ...COMSPHERE 3550 Series Data Service Units C July 1999 3550 A2 GB20 40 Notices ...
Page 12: ...COMSPHERE 3550 Series Data Service Units vi July 1999 3550 A2 GB20 40 ...
Page 68: ...COMSPHERE 3550 Series Data Service Units 4 22 July 1999 3550 A2 GB20 40 ...
Page 98: ...COMSPHERE 3550 Series Data Service Units 5 30 July 1999 3550 A2 GB20 40 ...
Page 100: ...COMSPHERE 3550 Series Data Service Units A 2 July 1999 3550 A2 GB20 40 ...
Page 101: ...DSU Menu A 3 3550 A2 GB20 40 July 1999 ...
Page 108: ...COMSPHERE 3550 Series Data Service Units B 6 July 1999 3550 A2 GB20 40 ...
Page 122: ...COMSPHERE 3550 Series Data Service Units C 14 July 1999 3550 A2 GB20 40 ...
Page 129: ...Pin Assignments D 7 3550 A2 GB20 40 July 1999 Figure D 5 EIA 232 D Crossover Cable 4951 035F ...
Page 134: ...COMSPHERE 3550 Series Data Service Units E 4 July 1999 3550 A2 GB20 40 ...