14
Table 7. Management – General Configuration Options (1 of 2)
Option
Factory 1
Factory 2
Comments/Description
SNMP Mgt:
Disab
Disab
Specifies whether the DSU/CSU
responds to SNMP session
SNMP Mgt:
Enab
Enab
p
responds to SNMP session
requests.
NMS Valid:
Disab
Disab
Specifies whether the DSU/CSU
validates the IP address of an
NMS Valid:
Enab
Enab
validates the IP address of an
SNMP manager attempting
access.
Num Sec Mgrs:
1
2–10
1
2–10
The number of management
systems authorized to send SNMP
messages to this unit.
NMS
n
IP Adr:
Edit
Edit
Specifies the IP address for each
NMS This configuration option is
NMS
n
IP Adr:
Clear
Clear
p
NMS. This configuration option is
repeated for all
n
NMSs.
NMS
n
ACS:
Read
Read
The type of access allowed for
NMS
n
ACS:
R/W
R/W
The type of access allowed for
NMS
n
.
System Name:
Edit
Edit
The SNMP system name for this
System Name:
Clear
Clear
The SNMP system name for this
device.
System Location:
Edit
Edit
The SNMP system location for this
System Location:
Clear
Clear
The SNMP system location for this
device.
System Contact:
Edit
Edit
The SNMP system contact name
System Contact:
Clear
Clear
The SNMP system contact name
for this device.
CommunityName1:
Edit
Edit
A community name that is allowed
access to this device Defaults to
CommunityName1:
Clear
Clear
y
access to this device. Defaults to
public
.
Access 1:
Read
Read
The type of access allowed for
Access 1:
R/W
R/W
The type of access allowed for
community name 1.
CommunityName2:
Edit
Edit
A community name that is allowed
CommunityName2:
Clear
Clear
A community name that is allowed
access to this device.
Access 2:
Read
Read
The type of access allowed for
Access 2:
R/W
R/W
The type of access allowed for
community name 2.
IP Adr:
Edit
Edit
The IP address needed to access
IP Adr:
Clear
Clear
The IP address needed to access
the device.
NetMask:
Edit
Edit
The Subnet Mask needed to
NetMask:
Clear
Clear
The Subnet Mask needed to
access the device.
Com IP Adr:
Edit
Edit
The IP address for the COM port
Com IP Adr:
Clear
Clear
The IP address for the COM port
when configured for SNMP.
All manuals and user guides at all-guides.com