background image

 3

7612-A2-GN10-20

December 1998

4. Insert the other end of the cable into the appropriate port of a

VT100-compatible terminal, PC, or modem.

The DSU has the factory-loaded set of VT100-compatible defaults for the
asynchronous terminal of 9.6 kbps, 8 bits per character, one stop bit, and no
parity.

5. Insert one unkeyed 8-pin connector on the Ethernet cable into the 10BaseT

port.

6. Insert the other end of the cable into the LAN interface.

7. Insert one end of the 34-pin V.35 cable into the DTE port.

8. Insert the other end of the V.35 cable into the DTE connector.

9. Insert the keyed 8-pin connector on the RJ48S network cable into the

NETWORK port.

10. Insert the other end of the cable into the RJ48S modular jack.

97-15310

RJ48S

Jack

NETWORK

TERMINAL

POWER

D
T
E

DTE

10BaseT

Connection

Terminal

Connection

Power

Connection

 Network

Connection

 DTE

Connection

10BaseT

LAN

CAUTION:

Use no power supply except the one provided with the DSU. Using the
wrong power supply can destroy the DSU.

Summary of Contents for 7612

Page 1: ...is available at www paradyne com Select Service Support Technical Manuals Subrate Digital Access Devices Select the following document 7612 A2 GB20 Model 7612 SNMP DSU with Internal Ethernet LAN Adap...

Page 2: ...ables For detailed information refer to Appendix E Cables and Pin Assignments in the User s Guide Before Installation Before installation read the Important Safety Instructions on page 7 Make sure you...

Page 3: ...er end of the cable into the LAN interface 7 Insert one end of the 34 pin V 35 cable into the DTE port 8 Insert the other end of the V 35 cable into the DTE connector 9 Insert the keyed 8 pin connecto...

Page 4: ...1 0 4 R T S 1 0 5 D T R 1 0 8 7612 SNMP DSU Verify that the User Interface Idle screen is displayed on the asynchronous terminal or PC Press the Enter key Verify that the Main Menu appears main Access...

Page 5: ...ing an external modem through the Terminal port Fill in the Identity screen Refer to Chapter 3 Configuring the DSU Establish security and Login IDs Refer to Chapter 4 Security Decide on an IP addressi...

Page 6: ...ogin administration or to initiate a power up reset of the DSU Configuration Edit Display System Network Data Port Ethernet Port Terminal Port Telnet Session SNMP Load Configuration from Status System...

Page 7: ...7 A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a h...

Page 8: ...sing equipment regulations Cet appareil num rique de la classe A respecte toutes les exigences du r glement sur le mat rial brouilleur du Canada Government Requirements Certain governments require tha...

Page 9: ...protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the...

Page 10: ...sales service repair installation documentation training distributor locations or Paradyne worldwide office locations use one of the following methods H Via the Internet Visit the Paradyne World Wide...

Reviews: