Hardware Verification

Verify that the OK LED is on.

Verify that the ALARM LED is off.

97-15273

Network

System

Port

56/64K

CTS (106)

OK

ALARM TEST

DM

OOS

OOF

NS

TXD (103)RXD (104)R

TS (105)

DTR (108)

7612 SNMP DSU

Verify that the User Interface Idle screen is displayed on the asynchronous
terminal or PC.

Press the Enter key. Verify that the Main Menu appears.

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎÎ

main

Access Level: 1

Device Name: 

Model: 7612

MAIN MENU

Status

Test

Configuration

Control

––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––

Ctrl-a to access these functions

Exit

 If your DSU fails to respond as described, refer to Chapter 8, 

Messages and

Troubleshooting, in the User’s Guide.

 

Summary of Contents for 7612 SNMP DSU

Page 1: ...CHANGE Please note that the area code for Paradyne Corporation in Largo Florida has changed from 813 to 727 For any Paradyne telephone number that appears in this manual with an 813 area code dial 72...

Page 2: ...ctions An operable network connection An operable LAN connection An asynchronous terminal or personal computer PC Package Checklist Verify that your package contains the following A Model 7612 Single...

Page 3: ...ith DB25 plug connectors on both ends A DTE with a V 35 connector to the DTE port V 35 cable with an MS34 plug connector on one end and an MS34 socket connector on the other end Contact your sales or...

Page 4: ...rt of a VT100 compatible terminal PC or modem The DSU has the factory loaded set of VT100 compatible defaults for the asynchronous terminal of 9 6 kbps 8 bits per character one stop bit and no parity...

Page 5: ...0 4 R T S 1 0 5 D T R 1 0 8 7612 SNMP DSU Verify that the User Interface Idle screen is displayed on the asynchronous terminal or PC Press the Enter key Verify that the Main Menu appears main Access L...

Page 6: ...hannel IMC Out of band using an external modem through the Terminal port Fill in the Identity screen Refer to Configuring the DSU Chapter 3 Establish security and Login IDs Refer to Security Chapter 4...

Page 7: ...in administration or to initiate a power up reset of the DSU Configuration Edit Display System Network Data Port Ethernet Port Terminal Port Telnet Session SNMP Load Configuration from Status System a...

Page 8: ...A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings If products installed in separate buildings are interconnected the voltage potential may cause a haz...

Page 9: ...ng equipment regulations Cet appareil num rique de la classe A respecte toutes les exigences du r glement sur le mat rial brouilleur du Canada Government Requirements Certain governments require that...

Page 10: ...otective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements document s The Department does not guarantee the equipment will operate to the u...

Page 11: ...uipment is in need of repair refer to the following section Warranty Sales and Service Information Contact your sales or service representative directly for any help needed For additional information...

Reviews: