Configuration Option Tables
A-7
7610-A2-GB20-00
November 1996
Table A-2.
Network Interface Options (3 of 4)
No Signal Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When a NS condition is detected on the network interface, an ASCII alarm is generated.
Enable – Generates an ASCII alarm when a no signal condition is detected.
Disable – No ASCII alarm is generated.
NOTE:
Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section in Chapter 8.
Out of Service Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When an OOS condition is detected on the network interface, an ASCII alarm is
generated.
Out of Service Alarm option appears when the
Operating Mode
is set to DDS in
Table A-1.
Enable – Generates an ASCII alarm when an out of service condition is detected.
Disable – No ASCII alarm is generated.
NOTE:
Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section in Chapter 8.
Out of Frame Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When an OOF condition is detected on the network interface, an ASCII alarm is
generated.
Enable – Generates an ASCII alarm when an out of frame condition is detected on the
network interface.
Disable – No ASCII alarm is generated.
NOTE:
Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section in Chapter 8.
Excessive BPV Alarm
Possible Settings: Enable, Disable
Default Setting: Enable
When a Bipolar Violation condition is detected on the network interface, an ASCII alarm
is generated.
Enable – Generates an ASCII alarm when an excessive BPV condition is detected.
Disable – No ASCII alarm is generated.
NOTE:
Additional settings are required to send out an ASCII alarm. Refer to the
Alarm Messages
section
in Chapter 8.