Enter section 

[4003]

.

2.

Enter the eight-digit module serial number.

3.

Enter the three-digit module section number.

Module Tamper on Input-8

Section 001 - Bit 1, 

0 = Disabled

, 1 = Enabled

Note: If this option is enable the on-board tamper is disabled.

EOL/ATZ per Zone Input

Section 401 - Zone Input Options

 Zone Input Options Individual Settings

EOL Resistor Value Selection

Section 402 - Zone Input Options

Zone Input Options Individual Settings

Programming MG/SP

1.

Enter section 

[001]

 -

 [032]

.

2.

Enter the two-digit zone definition.

3.

Assign a partition.

4.

Select or deselect zone options.

5.

Press Enter.

6.

Repeat steps 1 - 5 for remaining zones.

For more information on how to program zones, please refer to the MG/SP 
Programming Guide. 

Module Tamper on Input-1

Section 706 - Panel Programming

Note: If this option is enable the on-board tamper is disabled.

MG/SP Jumper Settings (Panel ATZ Off)

MG/SP Jumper Settings (Panel ATZ On)

 

Zone1 / Zone2

Zone3 / Zone4

Zone5 / Zone6

Zone7 / Zone8

_ / _

(0/0)

_ / _

(0/0)

_ / _

(0/0)

_ / _

(0/0)

OPTION DESCRIPTION

0

System default; zone will follow global panel settings for EOL

1

EOL / ATZ disabled

2

EOL enabled / ATZ disabled

3

EOL disabled / ATZ enabled

4

EOL / ATZ enabled

Zone1 / Zone2

Zone 3 / Zone4

Zone5 / Zone6

Zone7 / Zone8

_ / _

(0/0)

_ / _

(0/0)

_ / _

(0/0)

_ / _

(0/0)

OPTION

EOL Value

Zone Value

0

1K

1K

1

2K2

1K5

2

3K3

3K3

3

4K7

4K7

4

4K7

6K8

5

2K2

4K7

6

8K2

8K2

7

2K2

2K2

Option

Description

Off

ON

4

ZX82 ID A (panel +1) Input 1

Zone input

Tamper input

5

ZX82 ID B (panel + 9) Input 1

Zone input

Tamper input

6

ZX82 ID C (panel + 17) Input 1

Zone input

Tamper input

Module # 
(Jumper)

MG5000 MG5050 SP4000 SP5500 SP6000 SP65 SP7000

+1

3-10

6-13

5-12

6-13

9-16

10-17 17-24

+2

11-18

14-21

13-20

14-21

17-24

18-25 25-32

+3

19-26

22-29

21-28

22-29

25-32

26-32 N/A

Module # 
(Jumper)

MG5000 MG5050 SP4000 SP5500 SP6000 SP65

SP7000

+1

5-12

11-18

9-16

11-18

17-24

19-26 N/A

+9

13-20

19-26

17-24

19-26

25-32

27-32 N/A

+17

21-28

27-32

25-32

27-32

N/A

N/A

N/A

Warranty

For complete warranty information on this product, please refer to the Limited Warranty Statement 
found on paradox.com/terms or contact your local distributor. Specifications may change without prior 
notice.

Patents

US, Canadian and international patents may apply. Paradox is a trademark or registered trademark of 
Paradox Security Systems (Bahamas) Ltd.

All manuals and user guides at all-guides.com

Reviews: