[003]-[017]

Odd Numbered

Input Speed (Time Value)

Odd numbered sections represent inputs Z1 to Z8. Enter a 3-digit decimal time value (000 to 255). Multiply by the Input Speed. 

[018]

PGM Timer

Enter a 3-digit decimal value (001-255). Multiply by the PGM Base Time Selection.

[019]

[020]

[021]

[022]

Activation Event*

__/__/__ Event Group 

__/__/__ Feature Group  

__/__/__ Start# Set the range within the Feature Group  

__/__/__ End# Set the range within the Feature Group

[023]

[024]

[025]

[026]

Deactivation Event*

__/__/__ Event Group 

__/__/__ Feature Group  

__/__/__ Start# Set the range within the Feature Group 

__/__/__ End# Set the range within the Feature Group

[030]

PGM Test Mode

Activate PGM for 8 seconds to verify if the PGM is functioning properly.

[401]

EOL/ATZ Options per  Zone Input

By default, all options are configured as “0”. This means that all zone inputs will follow the global setting at panel section

[3033]

, options 7 and 8. However,       if you change the value from 1 to 4, the inputs will follow the desired settings as shown below.:

Zone Input Option Individual Settings

[402]

 Selectable Input Resistor for EOL and Contact

Zone Input Option Individual Settings

Default Setting / *Only Event Groups 000 to 055 can be used. See PGM Table in the panel’s Programming Guide.

Programming Method

1. 

[

ENTER

[

INSTALLER

 

CODE

]

2. Enter 

[

SECTION

]

 and turn desired option ON/OFF or enter the required data

[650]

Tamper Recognition

[1]

 EOL Zones

OFF

 = No EOL

ON

 = With EOL 

[2]

 Tamper Recognition

OFF

 = Disabled

ON

 = Enabled (Z1)

[3]

 PGM Follows Global PGM

OFF

 = Disabled

ON

 = Enabled

[651]

Zone Assignment

Enable zone inputs. Options [1] to [8], represent inputs Z1 to Z8.

[655]

PGM Timer

__/__/__   000 - 255 sec.   000 = Follow Deactivation Event.

[656]

PGM Activation Event

__/__ Event Group 

[60]

 Tamper zone opened 

[61]

 Tamper zone closed

__/__ Sub-Group 

[1]

 to 

[8]

 Zone input Z1 to Z8

 r

e

t

n

E

 :

d

e

s

U

 t

o

N

n

o

it

it

r

a

P

 

_

_

/

_

_

[00]

 

[657]

PGM Deactivation Event

__/__ Event Group 

[60]

 Tamper zone opened 

[61]

 Tamper zone closed

__/__ Sub-Group 

[1]

 to 

[8]

 Zone input Z1 to Z8

 r

e

t

n

E

 :

d

e

s

U

 t

o

N

n

o

it

it

r

a

P

 

_

_

/

_

_

[00]

 

Option

Description

0

System default, zone will follow global panel settings for EOL and ATZ set in section [3033]. options 7 & 8.

1

No EOL, No ATZ

2

EOL enabled, No ATZ 

3

No EOL, ATZ enabled

4

EOL enabled, ATZ enabled

Option

EOL Value

Zone  A Value

Zone B Value(ATZ)

2

K

2

K

1

K

1

0

A

/

N

5

K

1

2

K

2

1

A

/

N

3

K

3

3

K

3

2

A

/

N

7

K

4

7

K

4

3

A

/

N

8

K

6

7

K

4

4

A

/

N

7

K

4

2

K

2

5

A

/

N

2

K

8

2

K

8

6

Reviews: