SR120-EI02 12/2012
SR120 V1.0
PARADOX.COM
Programming
Upgrading the Firmware
The SR120 firmware can be upgraded through InField (V3.0 or higher) using the 307USB Direct Connect Interface. Refer to the firmware upgrade
instructions found at: paradox.com - Software - WinLoad -Firmware Upgrade Instructions.
NOTE:
Ensure that the SR120 Wireless Siren is awake before beginning the firmware upgrade. To wake up the siren, press the “test” button. The siren will
provide you with a 60 second delay in order to begin the update.
Tamper Supervision
If a tamper is detected, the SR120 will sound an alarm and the strobe light will flash for 4 minutes. The control panel will follow the global supervision
options set in the panel.
For complete warranty information, please visit www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all warranty terms and conditions. Magellan, Spectra SP, EVO, and WinLoad are
trademarks or registered trademarks of Paradox Ltd. or its affiliates in Canada, the United States and/or other countries. For the latest product approvals, such as UL and CE, please visit www.paradox.com. © 2012 Paradox
Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, and RE39406 and
other pending patents may apply. Canadian and international patents may also apply.
Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.
LED Feedback
Specifications
Power
4.5Vdc (3 size “C” alkaline batteries)
Battery life
Up to 3 years based on normal use (e.g., 2 alarms per year
with strobe for 2.5 hours and 8 squawks per day at an
average of 25
º
C (77
º
F) with default alarm time set to 4
minutes. If the alarm is set for more than 4 minutes, the
battery life may be reduced).
RF frequency
433MHz or 868MHz
Siren
100dB or more (1 meter)
Dimensions
15.2cm X 4.6cm X 10.9cm (6in X 1.8in X 4.3in)
Weight
24g (.85oz) without batteries
Humidity range
5% to 90%
Operating
Temperature
-20ºC to 50ºC (-4ºF to 122ºF)
RF range
70m (230ft)
MG/SP
Feature
Details
[683]
Learn Siren #1
Press and hold “TEST” switch for 2 seconds after entering the section
to learn the siren.
WARNING:
When you press the “TEST” switch, the SR120 will squawk and
the strobe light will flash five times to confirm registration to the panel.
[684]
Learn Siren #2
[685]
Learn Siren #3
[686]
Learn Siren #4
[687]
Display Signal Strength Siren #1
Press and hold “Test” switch for 3 seconds after entering the section
to display the signal strength the panel is receiving from the siren (on
a K32LCD v1.3 or higher, or a K32LX v1.0 or higher).
[688]
Display Signal Strength Siren #2
[689]
Display Signal Strength Siren #3
[690]
Display Signal Strength Siren #4
[691]
Label Siren #1
These labels are used when reporting events via e-mail through the
IP100 and for troubleshooting purposes. Maximum 16 characters.
[692]
Label Siren #2
[693]
Label Siren #3
[694]
Label Siren #4
[695]
Temporary Tamper Switch Deactivation for
Maintenance
Press the
[
ENTER
]
key after entering the section to deactivate tamper
alarm until the cover is replaced or after 30 minutes.
[587]
Panel Supervision of Siren
OFF = disabled ON = enabled (default)
Option [3]
Siren #1 (OFF/ON)
The control panel supervises the presence of the SR120. If lost, the
control panel will follow global supervision loss option set in the
panel.
Option [4]
Siren #2 (OFF/ON)
Option [5]
Siren #3 (OFF/ON)
Option [6]
Siren #4 (OFF/ON)
Signal strength/
RF transmission
LED
Red blink - sending data
Green blink - receiving data
Amber flash 4x - strong signal
Amber flash 3x - good signal
Amber flash 2x - weak signal
Amber flash 1x - very weak signal (relocate)
No flash - no signal
Status LED
Red steady on - powered/normal operation
Red slow blink - low battery