Step 3: Optional Settings
Partitioning
(to enable 2 partitions)
Enable Bell Squawk when arm/disarm
with Keypad / Generic Remote Control
Change Installer Code (Default: 0000)
Change Master Code (Default: 1234)
Reset All Programming to Default
Remote Control Assignment
611 for Rem#1, 612 for Rem#2,… up to 642 for Rem#32
Enroll Remote Control (REM15)
651 for Rem#1, 652 for Rem#2,.. Up to 682 for Rem#32
Step 4: Set Telephone Programming (Dial Out when alarm triggers)
Set Dialing attempts
Activate VDMP3 function*
Rings to pickup by panel*
*Only required if VDMP3 Voice Module installed
To be done in Standby Mode (Exit Programming Mode first):
Set to dial telephone #1
Set to dial telephone #2
Set to dial telephone #3
Set to dial telephone #4
Set to dial telephone #5
Step 5: Set Central Monitoring Station (CMS) Function
(only required if connected to ADT, CHUBB, PROTECS etc)
Set Contact ID Format
Set Account number Partition 1
Set Account number Partition 2
Set Telephone 1 (primary)
Set Telephone 2 (secondary)
Set Alternate Dial:
Set always report disarm
Set send daily test report
Set time for test signal
Step 6: Perform Walk Test
The Installer Test mode will allow you to perform walk tests where the siren will squawk to indicate opened zones.
To Activate: [ENTER] [INSTALLER CODE] [TBL] [CLEAR]
To DeActivate: [ENTER] [INSTALLER CODE] [TBL] [CLEAR]
Step 7: Hard Reset Panel
If settings have been entered wrongly and the panel does not work as desired, panel can be reset by doing the following:
i) Press & Hold Reset button on Main Panel for 5 seconds, then notice the Status LED blinking.
ii) Once blinking, quickly release the button and press again one time to reset to factory defaults.
Prepared by:
Belco Security Sdn Bhd
14, Jalan Intan 1, Taman Puchong Intan, 47150
Puchong, Selangor. Tel: 03-8062 3100 Fax: 03-9235 1118
651
Description
Command
Confirm
Timer & Option
611
950
ENTER, CLEAR
704
ENTER, CLEAR
399
397
700
New Code: XXXX
New Code: XXXX
(Default is OFF)
ON key [5]
Description
Command
Section
Timer & Option
Confirm
(Auto call the secondary number if primary
number is busy)
ENTER
Telephone number 2
817
ENTER
Telephone number 1
815
4 digit Account number
812
Section
841
(Default is OFF)
ON key [1]
Press and Hold any button for
2 times
ENTER, CLEAR
[1888] [8888]
ENTER
Command
Description
005
ENTER, CLEAR
ENTER, CLEAR
010
On key [8]
901
703
[ ] + [Master code] + [MEM] + [7] + [5th phone number] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [6] + [4th phone number] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [5] + [3rd phone number] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [4] + [2nd phone number] + ENTER, CLEAR
[ ] + [Master code] + [MEM] + [3] + [1st phone number] + ENTER, CLEAR
ENTER, CLEAR
4 digit Account number
811
4, 4
810
Confirm
Timer & Option
Section
ENTER, CLEAR
On key [4]
800
850
[ HH:MM ]
ENTER, CLEAR
001
840
ENTER, CLEAR
Off key [1]
801