Quick User Guide for Paradox
Spectra SP Series
SYSTEM MASTER CODE
1234
1) How to ARM the alarm system
a) How to do (REGULAR ARMING) the alarm system
Hold [ARM] 3 seconds or [ARM] + [Access code]
b) How to do (STAY ARMING) the alarm system
Hold [STAY] 3 seconds or [STAY] + [Access code]
c) How to do (SLEEP ARMING) the alarm system
Hold [SLEEP] 3 seconds or [SLEEP] + [Access code]
2) How to DISARM the alarm system
[OFF] + [Access Code]
3) How to BYPASS a zone
SP Series panel does not allow the system to be armed when
there is a defective sensor. User will need to manually
BYPASS the zones where the defective sensor is installed.
4) How to view most recent alarm trigerred zone
After the alarm triggered, all triggered zone will be stored in
Press [MEM] Key
memory. The [MEM] key will light on.
Press [CLEAR] to Exit
5) How to change System Master code?
System Master code belongs to the owner. Master code can
add/edit/delete Access codes.
6) How to create Access Code?
Access code is assigned to the tenant that is renting the room.
After tenant stops renting, owner can use the Master code
to delete the old Access code and assign a new Access Code
to new tenant.
7) How to check Panel problem?
Press [TBL] and the keypad numbers will light up corresponding
When there is technical problem arise, the [TBL] light on
to the problem detected.
keypad will turn on.
[2] Power trouble
[3] Bell (Siren) trouble
[4] Communication trouble
[8] Timer loss
[0] Module Supervision Loss
Press the number to see more details on the problems detected.
[2] Power trouble
[1] Panel low battery
[2] AC power loss
[3] Aux. overload on panel
[3] Bell (Siren) trouble
[1] Bell disconnected
[2] Bell overload
[4] Communication trouble
[1] Telephone line monitoring on control panel
[2] Fail to communicate on CMS telephone 1
[3] Fail to communicate on CMS telephone 2
[4] Fail to communicate on pager
[5] Fail to communicate on voice telephone
[6] Fail to communicate with PC
[8] Timer Loss
Set current date & time:
[TBL] + [8] + [HH:MM] (key in 12 hours format) + [2=am, 3=pm]
+ (YYYY) + (MM) + (DD) + [CLEAR]
[0] Module Supervision Loss
To clear bus module trouble:
Enter Programming Section 955 > Wait few seconds to refresh
v1.1 (Aug'13)
Prepared by:
Belco Security Sdn Bhd
14, Jalan Intan 1, Taman Puchong Intan, 47150
Puchong, Selangor. Tel: 03-8062 3100 Fax: 03-9235 1118
[ ] + [System Master Code] + [01] + [New System Master Code] +
[Repeat New System Master Code] + [ENTER, CLEAR]
[ ] + [System Master Code] + [04] + [New Access Code] + [Repeat
New Access Code] + [ENTER, CLEAR]
[BYP] + [Access Code] + (2-digit Zone Numbers) + [ENTER]