SP+ Series Programming Guide
45
System Trouble Report Codes
Use worksheet 42 to record your settings for system
trouble report codes.
System Trouble Restore Codes
Use worksheet 43 to record your settings for system
trouble restore codes.
System Special Report Codes
Use worksheet 44 to record your settings for system
special report codes.
NOTE:
For report code formatting instructions, see
Installer Function Keys
Worksheet 42: Special Trouble Report Codes
Section
Data
Description
Section
Data
Description
Section
Data
Description
[865]
___/___
-
[866]
___/___
Bell output overload
[867]
___/___
Fail to communicate
___/___
AC failure
___/___
Bell output disconnected
___/___
RF jamming
___/___
Battery failure
___/___
Timer loss
___/___
Module lost
___/___
Auxiliary supply
___/___
Fire loop trouble
___/___
Module tamper
[868]
___/___
Module power fail
[869]
___/___
Wireless module
supervision lost
Default: FF
___/___
Module low/no battery*
___/___
Wireless module tamper
___/___
Wireless zone low battery
___/___
Remote low battery
___/___
Wireless zone supervision lost
___/___
-
Worksheet 43: System Trouble Restore Codes
Section
Data
Description
Section
Data
Description
Section
Data
Description
[870]
___/___
TLM
[871]
___/___
Bell output overload
[872]
___/___
Fail to communicate
___/___
AC failure
___/___
Bell output disconnect
___/___
RF jamming
___/___
Battery failure
___/___
Timer loss
___/___
Module lost
___/___
Auxiliary supply
___/___
Fire loop trouble
___/___
Module tamper
[873]
___/___
Module power fail
[874]
___/___
Wireless module
supervision lost*
Default: FF
___/___
Module low/no battery*
___/___
Wireless module tamper
___/___
Wireless zone low battery
___/___
Remote low battery
___/___
Wireless zone supervision lost
___/___
-
Worksheet 44: System Special Report Codes
Section
Data
Description
Section
Data
Description
Section
Data
Description
[875]
___/___
Cold start
[876]
___/___
Installer in
[877]
___/___
-
___/___
Test report
___/___
Installer out
___/___
-
___/___
-
___/___
Closing delinquency
___/___
-
___/___
Software out
___/___
-
___/___
Fail to arm
Default: FF
Table 40: Description of installer functions for SP+ keypads
Function Action
Description
Test report
ENTER
+ installer code +
ENTER
Sends the
Test Report
report code programmed in section
[875]
, to the monitoring station.
Cancel communication
ENTER
+ installer code +
STAY
Cancels all communication with the BabyWare software or with the monitoring station, until the next
reportable event.
Answer BabyWare
software
ENTER
+ installer code +
SLEEP
Will force the console to answer an incoming call from the monitoring station, which is using the
BabyWare software.
Call BabyWare
software
ENTER
+ installer code +
BYP
Will dial the PC telephone number programmed in section
[915]
, thereby initiating communication
with a computer using the BabyWare software.
Installer test mode
ENTER
+ installer code +
TBL
This mode allows to perform walk tests, where the siren will squawk to indicate opened zones.
To exit, press
TBL
.