Programming
Page 13
[2851]
to
[2858]
Learn Siren
Press and hold the
Reset/Training
switch for 3 seconds after entering the
section to learn the siren
WARNING
: When pressing the Reset/
Training switch, the SR130/SR150
squawks and the strobe light flashes
five times to confirm siren registration
to the panel
[2861]
to
[2868]
Assign Partition to
Siren
Assign sirens to either one partition or
to all eight partitions.
00
: Assigned to ALL 8 partitions
01-08
: Assign to selected partition
[2871]
to
[2878]
Display Siren Signal
Strength
Press and hold the
Reset/Training
switch for 3 seconds after entering the
section to display the siren signal
strength that the panel receives.
Requires keypad K32LCD V1.3 and
higher
[2870]
Temporary Siren
Tamper Switch
Deactivation for
Maintenance
Press
[
ENTER
]
after entering the section
to deactivate tamper alarm until the
cover is reinstalled or after 30 minutes
Section
Feature
Details