Paradox PCS260 Installation And Programming Manual Download Page 2

PARADOX.COM

GSM Reporting (EBUS Connection)

Reporting Options

SMS Messages for Backup 

Additional Programming Options

SMS Language

List of SMS Commands

Technical Specifications

Safety Note: 

This device may operate continuously in temperature of 55°C 

(

131°F)

 for a maximum period of 7 days.

If you have any comments please write to us at Paradox.com/products/
feedback.

Receiver Settings MG/SP

Receiver #:
IP address*
IP port ** 
IP address WAN 2
IP port WAN2
Receiver password
Security Profile

1
[929}
[930]
[931]
[932]
[933]
[934]

2
[936}
[937]
[938]
[939]
[940]
[941]

Backup
[943}
[944]
[945]
[946]
[947]
[948]

Module registra-
tion - Press 

[ARM]

 

to register

[935]

[942]

[949]

Receiver Settings EVO

Receiver #:
IP address*
IP port **
IP address WAN 2
IP port WAN2
Receiver password
Security Profile

1

[2984]

2

[2986]

3

[2988]

4

[2990]

* For 1 or 2 digit numbers, add “0’s” before the digit: e.g., 
138.002.043.006
** Default = 10000
Enter [MEM] for blank space

MG/SP

EVO

Details

[805]

[2950]

[1] Off + [2] Off = landline only (default)
[1] Off + [2] On = landline primary / GSM 
backup (default)
[1] On + [2] Off = GSM primary / landline 
backup
[1] On + [2] On = GSM only

[815] to
[817]

[3071] to 
[3074]

Telephone numbers

[811] to 
[812]

[3061] to
[3068]

Account numbers

Command

Description

P[PASSWORD].SMS[GSM MODEM 
TELEPHONE #].[IPRS-7 PASSWORD]

Used to program the 
receiver’s SMS parameters

Language

Value

Language

Value

English (default)

000

Bulgarian

016

French

001

Romanian

017

Spanish

002

Slovak

018

Italian

003

Chinese

019

Swedish

004

Serbian

020

Polish

005

Malay

021

Portuguese

006

Slovenian

022

German

007

Lithuanian

023

Turkish

008

Finnish

024

Hungarian

009

Estonian

025

Czech

010

French Canadian

026

Dutch

011

Belgian

027

Croatian

012

Latvian

028

Greek

013

Albanian

029

Hebrew

014

Macedonian

030

Russian

015

Command

Description

P[password].A[IP address].
P[port number]

Used for 3G/2G remote access

P[password].IP.[call back phone
number]

Used to obtain the IP address and IP 
port of the PCS260 and whether or 
not the
“bandwidth saver” option is being 
used

P[password].RESET

Used to reset the PCS260

P[password].BWS.ON

Used to enable bandwidth saver 
mode

P[password].BWS.OFF

Used to disable bandwidth saver 
mode

P[password].VOLOUT.[GSM 
output volume]

Used to set the GSM output volume; 
values range between 50 to 100

P[password].STATUS.[phone
number]

Used to obtain the signal strength, 
signal quality, 3G/2G connection 
status, and APN
settings of the current SIM card

P[password].APN1.NAME.
[Access Point Name]

Used to program the SIM Card 1 APN 

P[password].APN1.USER.[Access
Point Name]

Used to program the SIM card 1 APN 
User Name

P[password].APN1.PSW.[Access
Point Name]

Used to program the SIM card 1 APN 
Password

P[password].APN1.CLEAR]

Used to clear the SIM Card 1 APN

P[password].VAPN1.NAME.
[Access Point Name]

Used to view the SIM card 1 APN

P[password].APN2.NAME.
[Access Point Name]

Used to program the SIM card 2 APN

P[password].APN2.USER.[Access
Point Name]

Used to program the SIM card 2 APN 
User Name

P[password].APN2.PSW.[Access
Point Name]

Used to program the SIM card 2 APN 
Password

P[password].APN2.CLEAR 

Used to clear the SIM card 2 APN

P[password].VAPN2.[CALL BACK
PHONE NUMBER]

Used to view the SIM card 2 APN
information

P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/ IP3W2/
IP4W1/ IP4W2].[domain name]

Set domain name for 3G/2G receiver

P[password].[IP1W1/ IP1W2/
IP2W1/ IP2W2/ IP3W1/ IP3W2/
IP4W1/ IP4W2].CLEAR

Clear domain name for 3G/2G 
receiver

P[password].DNS.[ip address]

Set domain name server (DNS) IP 
address

Language

Value

Language

Value

P[password].DNS.CLEAR

Clear domain name server (DNS) IP 
address

P[password].VIP.[phone num-
ber]

Get domain name server (DNS) info

C[user code].[ARM/OFF].A[area
number], [area number], [area
number]TO[area number]

Arm/Disarm

Specifications

Description

RF Power

Class 4 (2W) @ 850/1900 MHz 
Class 2 (1W) @ 1800/1900 MHz 
UMTS 850/1900 @ 0.25W (America)
UMTS 900/2100 @ 0.25W (Europe)

Antenna Bandwidth

5 bands, wideband

Voltage Input

12 VDC nominal

Consumption during 
GPRS/GSM transmission

60mA standby
300 mA maximum

Encryption

128-bit 

SMS Protocol

7-bit (GSM: 3GPP TS 23.038/
GSM03.38)
or 16-bit (UCS2 ISO/IEC10646)

SIM Cards

UMTS (3G) 
GSM (2G - n/a for North and South 
America)

Humidity

0 - 90% non-condensing

Operating Temperature

-20 - 50 °C (-4 to 122 °F)

Dimensions

20.8 x 7.5 x 2 cm  / 8.2 x 2.9 x 0.8 in.

Command

Description

Warranty

The Limited Warranty Statement can be found on the website
www.paradox.com/terms.

Patents

Your use of the Paradox product signifies your acceptance of these terms and
conditions. The following US patents may apply 5,886,632 and 6,215,399. Other
Canadian and international patents may apply.

©2015 Paradox Security Systems (Bahamas) Ltd. All rights reserved.
Specifications may change without prior notice.