38
Programming Guide
Miscellaneous System Options
Unlock Panel Serial Ports
Enter section
[300]
to unlock your ’s panel serial ports for use with third-party devices using a TM70/TM50 Touch keypad or keypad. For a step-
by-step procedure, refer to the Insite Gold Installer Menu Guide.
System Timers
Use the following section to program system timers on your control panel. Use worksheet 28 to record your settings.
Keypad Lockout
Use the following section to program keypad lockout settings for your control panel. Use worksheet 29 to record your settings.
NOTE:
For EN 50131, the keypad lockout value must be set between three and ten attempts. The minimum delay to lock must be two minutes.
Programming the Daylight Savings Feature
Use the following section to program Daylight Savings Time on your control panel. Use worksheet 30 to record your settings.
Table 27: Description of section [708]
Option
Description
OFF
ON
Sec
tion
[708]
EN50131
OPT
ION
S
1
Enter code to view trouble
One-touch
Enter code
2
Enter code to view alarm in memory/event list
One-touch
Enter code
3
Trouble latch
Disabled
Enabled
4
Bell squawk on Installer in
Disabled
Enabled
5
Acknowledge trouble(s) before arming
Disabled
Enabled
6
Do not arm if zone opens during exit delay
Disabled
Enabled
7
Disable ‘Bypass and Arm’
Disabled
Enabled
8
Future use
= Default
Worksheet 28: System Timers
Section
Data
Description
Section
Data
Description
[710]
___/___/___
000 to 255 seconds Entry delay 1* (default: 045)
[718]
___/___/___
000 to 255 seconds
Remote panic disarm lock delay
(default: 000)
[711]
___/___/___
000 to 255 seconds Entry delay 2* (default: 045)
[719]
___/___/___
000 to 255 days
Closing delinquency delay
(default: 000)
[712]
___/___/___
000 to 015
Auto-zone shutdown counter
(default: 005)
[720]
___/___/___
000 to 255 seconds Flex-instant delay (default: 015)
[713]
___/___/___
000 to 255 seconds Intellizone delay (default: 048)
[721]
___/___/___
000 to 255 seconds
For StayD: re-arm delay
(default: 005)
[714]
___/___/___
000 to 255 minutes Recycle alarm delay (default: 000)
[722]
___/___/___
000 to 255 times
Auto trouble shutdown**
(default:000)
[715]
___/___/___
000 to 255
Recycle alarm counter
(default: 000)
[723]
___/___/___
000 to 255 seconds
Panic shutdown**
(default:000)
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10
Worksheet 29: Keypad Lockout
Section
Data
Description
Default
[716]
___/___/___
000 to 255 minutes
Keypad lockout delay
000
[717]
___/___/___
000 to 255 attempts before locking
Keypad lockout counter
000
Table 28: Description of section [730]
Section
Option
Description
OFF
ON
[730]
1
Daylight savings
Disabled
Enabled
= Default
Summary of Contents for MG5050+
Page 1: ...32 Zone Wireless Security System MG5050 Programming Guide ...
Page 63: ......