Magellan / Spectra SP
7
System Codes
Panel Reset
Performing a panel reset will reset all programmable sections to factory default values.
SP4000 panels:
1.
Verify installer lock is disabled.
2.
Remove the battery and AC power from the control panel.
3.
Remove all connected wires and devices from the PG1 and zone 1 terminals.
4.
Short the PG1 and zone 1 terminals with a wire.
5.
Reconnect the AC and battery power to the control panel.
6.
Wait for 10 seconds and remove the wire.
All other MG/SP panels:
To reset other MG/SP panels, press and hold the panel’s
RESET
button until the STATUS LED flashes (5 seconds). Release the
RESET
button and push it again within 2 seconds. Performing a manual panel reset will not clear bus module troubles.
To reset the panel to default using section programming, see section [950] in
Viewing Version Numbers
Installer Code (Default: 0000 / 000000)
The Installer code is used to enter programming mode, which allows you to program
everything except user codes. To change the default code, go to section [397] on
page 50 and refer to section [701] option [1] on page 50.
Maintenance Code (No Default)
The Maintenance code is used to enter programming mode, which allows you to
program everything except for user codes and communication settings (sections
[395], [397], [398], [815], [816], [817], [910], [911], [970], and [975]). To set the default
code, go to section [398] on page 50 and refer to section [701] option [1] on page 50.
System Master Code (Default: 1234 / 123456)
The System Master code can use any arming method and can program user codes.
To change the default code, go to section [399] on page 50 and refer to section [701]
option [1] on page 50.
Example:
Version
0
1.42
Digits 1-4
Step
Action
Details
When Viewing Keypad Version
1.
Enter Viewing Mode:
- For
panel version
, enter section
[980]
.
- For
keypad version
, enter Installer Programming,
then press and hold
[
ARM
]
.
The first digit is displayed
(usually “0”)
Digit 1
[
ARM
]
is illuminated
2.
Press
[
ENTER
]
The second digit is displayed
Digit 2
[
SLEEP
]
is illuminated
3.
Press
[
ENTER
]
The third digit is displayed
Digit 3
[
STAY
]
is illuminated
4.
Press
[
ENTER
]
The fourth digit is displayed
Digit 4
[
OFF
]
is illuminated
NOTE:
K10V/H / K636 keypad version numbers cannot be viewed.
Summary of Contents for MG5050