6
Programming Guide
Data Entry & Display
Each time the
[
ENTER
]
key is pressed, the keypad will display the next digit in the current section and will continue through all the
following sections one digit at a time without changing the programmed values. Not available for sections using the Multiple Feature
Select Method. Press the
[
CLEAR
]
key at any time to exit the Data Display Mode.
There are two methods that can be used to enter data when in programming mode: Single Digit Data Entry and Feature Select
Programming methods:
Single Digit Data Entry Method
After entering programming mode, some sections will require that you enter decimal
values from 000
to
255. Other sections will require
that you enter hexadecimal values from 0 to F. The required data will be clearly indicated in this manual. When entering the final digit in a
section, the panel will automatically save and advance to the next section. Refer to
Decimal and Hexadecimal Values
on page 6 to see the
keys and their equivalent decimal and/or hexadecimal value.
Feature Select Programming Method
After entering certain sections, eight options will be displayed where each option from
[1]
to
[8]
represents a specific feature. Press the
key corresponding to the desired option. This means the option is ON. Press the key again to remove the digit, thereby, turning OFF the
option. Press the
[
SLEEP
]
key to set all eight options to OFF. When the options are set, press the
[
ENTER
]
key to save and advance to the
next section.
Important Settings and Modes
Decimal and Hexadecimal Values
Section Description
[950]
Reset all programmable sections to factory default values
[955]
Clear bus module trouble (remove disconnected module from the bus)
[960]
Wireless transmitter serial number display (press any button on the assigned remote control or press the tamper switch of
the wireless module, then press
[
ENTER
]
to view the next digit)
[970]
Download memory key into panel (see the Reference & Installation Manual)
[975]
Upload panel into the memory key (see the Reference & Installation Manual)
[980]
Display version number of the panel (press
[
ENTER
]
to view the next digit)
Value or Action
What Do I Press?
What Do I See?
32-zone LED
10-zone LED
Value 0 / Replace Current
Digit with 0
[
SLEEP
]
Erase digit and remain in section
Erase digit and remain in section
Values 1 to 9
[1]
TO
[9]
Zone 1 to 9
Keys 1 to 9
A (hex only)
[0]
Zone 10
Key 0(10)
B (hex only)
[
OFF
]
Zone 11
OFF
C (hex only)
[
BYP
]
Zone 12
BYP
D (hex only)
[
MEM
]
Zone 13
MEM
E (hex only)
[
TBL
]
Zone 14
TBL
F (hex only)
[
]
Zone 15
[
]
Exit Without Saving
[
CLEAR
]
Arm & Stay LED flash
Arm & Stay LED flash
Save Data (hex only)
[
ENTER
]
Advances to the next section
Advances to the next section
K636
K10V/H
K35/K37
K32RF/K32
To access the Data Display Mode, press the
[
ENTER
]
key after entering a section and before entering any data. The four LEDs/Icon as
indicated below will begin to flash indicating that you are in the Data Display Mode.
Summary of Contents for MG5050
Page 71: ......