Programming Guide
13
Zone Recognition
NOTE:
For keypad zone programming, see
When expanding zones via ZX8/ZX82, up to three ZX8/ZX82 modules can be added to the system, and they are identified by the ZX8/ZX82 three-position jumpers:
+1, +9, and +17. Table 3 displays zone recognition information for control panels.
NOTE:
If a device is assigned to a zone which is already programmed, a wireless zone will overwrite a keypad/hardwire zone and a keypad zone will overwrite a
hardwire zone.
Table 3: Zone recognition information
Type
Zone
Description
Panel
1
Panel input 1
2
Panel input 2
3
Panel input 3
4
Panel input 4
5
Panel input 5
ZX8/ZX82 Jumper Panel + 1
6
Input 1
7
Input 2
8
Input 3
9
Input 4
10
Input 5
11
Input 6
12
Input 7
13
Input 8
ZX8/ZX82
Jumper Panel + 9
14
Input 1
15
Input 2
16
Input 3
17
Input 4
18
Input 5
19
Input 6
20
Input 7
21
Input 8
ZX8/ZX82 Jumper Panel + 17
22
Input 1
23
Input 2
24
Input 3
25
Input 4
26
Input 5
27
Input 6
28
Input 7
29
Input 8
-
30
-
31
-
32
-
Summary of Contents for MG5050+
Page 1: ...32 Zone Wireless Security System MG5050 Programming Guide ...
Page 63: ......