58
Magellan & Spectra SP • Installation Guide
System Settings
Version Number Display
Enter section
[980]
to view the version number of the panel. The first digit will appear. Press
[
ENTER
]
to scroll through each consecutive digit (the keypad will beep
twice after every digit in the version number). Once the version number has been fully displayed, an acknowledgment beep (3 beeps) will sound and the first digit
will be displayed again.
Push Button Power Reset
Performing a hardware reset will set all control panel settings to factory default except for the Panel ID and PC Password. Also, the event buffer will
not
be erased. To
perform a push button power reset:
Press and hold the RESET switch for five seconds. The STATUS LED will start flashing fast. Within 2 seconds of this flashing, press the reset switch again. The panel will
reset to default and restart
Installer Lock
Section
[395]
000 = Disabled, 147 = Lock Enabled, Default = Disabled
Program 147 into section
[395]
to lock all programming. Performing a hardware reset will not affect the current panel settings. To remove the Installer Lock, enter
000. Please note that three seconds after turning on the control panel the
STATUS
LED and the relay on the control panel will flash fast for 6 seconds to indicate that
the installer lock is enabled. Once enabled, the panel cannot be reset.
Keypad Lockout Feature
Sections
[864]
If a consecutive number of invalid codes are entered into a keypad, the control panel can be set to deny access from all keypads for a specified period and send the
report code programmed in section
[864]
. Program the number of consecutive invalid codes from 001 to 255 (000 = disabled) into section
[717]
. Program the
duration of the Keypad Lockout from 001 to 255 minutes into section
[716]
.
Battery Charge Current (not used for MG5075)
Section
[700]
: General Options
Option
[2]
OFF= Battery Charge Current: 350mA (default)
Option
[2]
ON= Battery Charge Current: 700mA (40VA transformer required)
Partitioning
Section
[700]
: General Options
Option
[1]
OFF= Partitioning Disabled (default)
Option
[1]
ON= Partitioning Enabled
The panel is equipped with a partitioning feature which can divide the alarm system into two distinct areas identified as Partition 1 and Partition 2. Partitioning can
be used in installations where shared security systems are more practical, such as an office/warehouse building. When partitioned, each zone, each user code (See
“Access Codes” on page 26) and some of the system's features can be assigned to Partition 1, Partition 2 or both.
If the system is not partitioned, all user codes and
features will be recognized as belonging to Partition 1.
•
Users can only arm partitions to which they have been assigned.
•
Only zones assigned to Partition 1 will arm/disarm when Partition 1 is armed or disarmed.
•
Only zones assigned to Partition 2 will arm/disarm when Partition 2 is armed or disarmed.
•
Zones assigned to both partitions will arm when both partitions are armed and will disarm when at least one disarms.
•
The following features can be programmed separately for each partition: Entry/Exit Delay Timer, Auto-arming Options, Bell Cut-Off Timer, Switch to Stay
arming, PGM Events and Account Numbers.
WARNING: If the system is not partitioned, all zones, user codes, and features will be recognized as belonging to partition 1. Zones that have been
manually assigned to partition 2 will no longer function.
Confidential Mode
Section
[701]
Options
[3]
,
[4]
and
[5]
Option
[3]
OFF= Confidential Mode Disabled (default)
Option
[3]
ON= Confidential Mode Enabled
Option
[4]
OFF= Keypads activate when an access code is entered (default)
Option
[4]
ON= Keypads activate when a key is pressed
Option
[5]
OFF= Confidential Mode Timer is 2 minutes (default)
Option
[5]
ON= Confidential Mode Timer is 5 seconds
If Confidential Mode is enabled and no actions are performed on the keypads for the time defined by the Confidential Mode Timer, all the keypad’s LEDs will be off
until either a key is pressed or an access code is entered. When the system exits Confidential Mode, the keypads will display the system’s status. Confidential Mode is
activated by enabling option
[3]
. Option
[4]
regulates whether the keypads will be activated at the touch of a key or only when an access code is entered. Option
[5]
determines the amount of time without action before the system enters Confidential Mode (5 seconds or 2 minutes).
Summary of Contents for Magellan MG5050E
Page 2: ......
Page 16: ...16 Magellan Spectra SP Installation Guide SP5500 8x10 SP6000 11x11 SP7000 11x11...
Page 67: ......