Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash. Programmed zones are lit (button or LED depending on keypad).
[
MAINTENANCE
CODE
]
may also be used.
2
[
ZONE
NUMBER
]
2 digits: 01 to 32
3
[E
NROLL
OR
ERASE
ZONE
]
Wireless zone = open/close cover or press learn/tamper switch. Hardwired zone =
Press [
ENTER
]. To erase a programmed zone, press [
SLEEP
] for 3 seconds.
4
[
ZONE
TYPE
]
Refer to page 6 for the zone type (zone definition).
5
Assign Partition
[1]
and/or
[2]
+
[
ENTER
]
Assign the zone to one or both partitions and press [
ENTER
]. By default, all zones are
assigned to partition 1. Goes to next available zone.
Step
Action
Details
1
[
ENTER
] + [
INSTALLER
CODE
]
[
ARM
] +
[
STAY
] = flash.
[
MAINTENANCE
CODE
]
may also be used.
2
Press and hold
(3sec)
[
ARM
]
+ [
STAY
]
= on.
3
[
ZONE
NUMBER
]
+
[
ENTER
]
*
K32LED / K32I = 2 digits: 01 to 32
K10V/H / K636 = 1 digit: 1 to 0(10) (can only assign zones 1-10)
* To erase a keypad zone number, press
[
CLEAR
]
, then
[
ENTER
]
.
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
3
[1]
= Entry Delay 1 (default = 045 sec.)
[2]
= Entry Delay 2 (default = 045 sec.)
[3]
= Exit Delay (default = 060 sec.)
[4]
= Bell Cut-Off (default = 004 min.)
4
[000]
to
[255]
Entry/Exit Delay = seconds / Bell Cut-Off = minutes
Step
Action
Details
1
+
[
INSTALLER
CODE
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
+ [5]
4
[
HH
:
MM
]*
Enter time.
5
[
YYYY
/
MM
/
DD
]
Enter date.