6
Programming Guide
Zone Definitions
To program zone definitions, zone partitions and assign options:
Table 1: Zone Definitions
Step
Action
Details
1
[
ENTER
] + [
INSTALLER
CODE
]
(default: 0000 / 000000)
[
ARM
]
+
[
STAY
]
= flash.
[
MAINTENANCE
CODE
]
may also be used.
2
Enter 3-digit zone you wish to program
[001]
to
[032]
[
ARM
]
+
[
STAY
]
= on (see table on page 7)
3
Enter a 2-digit zone definition
2 digits: 01 to 32 (see Table 1 below)
4
Assign Partition
[1]
,
[2]
or
[3]
By default, all zones are assigned to partition 1. (see Table 2)
5
Select or deselect zone options using
buttons
[1]
to
[8]
See Table 3 for zone options.
ON = feature activated
See Table 4 for keyswitch options.
OFF = feature deactivated
6
To save and proceed to the next zone,
press
[
ENTER
]
Zone Definitions
Stay Arm
Sleep Arm
Fully Arm
Zone Definitions
00 = Zone Disabled (default)
-
-
-
11
= Instant Fire†
01
= Entry Delay 1
Entry Delay 1
Entry Delay 1
Entry Delay 1
12
= Delayed Fire†
02
= Entry Delay 2
Entry Delay 2
Entry Delay 2
Entry Delay 2
13
= Instant Fire Silent†
03
= Entry Delay 1 (Full Arm)
Not Armed
Not Armed
Entry Delay 1
14
= Delayed Fire Silent†
04
= Entry Delay2 (Full Arm)
Not Armed
Not Armed
Entry Delay 2
15
= 24Hr. Buzzer
05
= Follow
Follow
*
Follow
*
Follow
*
16
= 24Hr. Burglary
06
= Follow (Sleep/Full Arm)
Not Armed
Follow
*
Follow
17
= 24Hr. Hold-up
07
= Follow (Full Arm)
Not Armed
Not Armed
Follow
18
= 24Hr. Gas
08
= Instant
Instant
*
Instant
*
Instant
*
19
= 24Hr. Heat
09
= Instant (Sleep/Full Arm)
Not Armed
Instant
*
Instant
20
= 24Hr. Water
10
= Instant (Full Arm)
Not Armed
Not Armed
Instant
21
= 24Hr. Freeze
18
= 24Hr. Gas
* Flex-Instant = Zone will follow the delay at section [720], (default is 15 seconds / 0 = instant zone)
19
= 24Hr. Heat
** On-board hardwire control panel zones 1 to 4 (E55) or 1 to 9 (E65)
20
= 24Hr. Water
† Only on-board zones can be defined as fire zones
21
= 24Hr. Freeze
†† This alarm will follow the Panic 1 option (section [702], option [1])
22
= 24hr. Panic††
23
= Follow No Pre-Alarm
NOTE: For more zone options, see sections [705] and [706] on page 8.
24
= Instant No Pre-Alarm
25
= Keyswitch Maintain**
26
= Keyswitch Momentary**
[1]- N/A
[2]- N/A
[3]- N/A
[4]
OFF = Disarm
ON = Disarm only if Stay/Sleep
armed
[5] = Arm only
[6] = Stay arming‡
[7] = Sleep arming‡
[8] = N/A
‡ Select only one. If all are off, key-
switch will regular arm.
[1] = Auto-zone Shutdown
[2] = Bypassable Zone
[3] = N/A
[4] [5]
OFF OFF Audible Alarm
OFF ON Pulsed Alarm
ON OFF Silent Alarm
ON ON Report Only
[6] = Intellizone
[7] = Delay alarm transmission
[8] = Force Zone
[1]- Partition 1
†
[2]- Partition 2†
[3]- Both partitions†
†
When using a K636 keypad, only
partition 1 is available. To use both
partitions, use a K10V/H, K32, or K32I
keypad.
Table 2 Partition Assignment
Table 3 Zone Options
Table 4 Keyswitch Options