32
Reference & Installation Manual
8.1
Timed Auto Arming
Feature Select Programming
D
Address 086; Key
[5]
Default: Timed Auto Arming Disabled
The alarm system will automatically arm itself at a specified time every day. Please note that as with Regular arming, the system
will not arm if a zone is open, but will always report a "late to close" to the monitoring station. If this occurs, the system will not
arm until the next day. If arming is successful, the arming report codes and a “late to close” are both transmitted to the monitoring
station. If arming is unsuccessful, only the “late to close” is sent to the monitoring station. The type of arming is dependent on the
Auto Arming Options (see
on page 32). Program the Auto Arm Time as described below:
8.1.1
Auto Arm Time
The control panel will automatically arm itself at the specified time if timed auto arming (see above) is enabled. The
time is programmed using the 24-hour clock (i.e. 8:00 p.m. = 20:00). There are two methods of programming the auto
arm time as described below.
Decimal Programming
D
Addresses 044 and 045
Program the Auto Arm Time in hours into address 044 and the Auto Arm Time in minutes into address 045.
[
ENTER
]
+ Installer code +
[0] [4] [4]
+ 3-digit decimal value (hours) +
[0] [4] [5]
+ 3-digit decimal value (minutes) +
[
ENTER
]
Key Access Programming
D
Key
[9]
The User 1, Master, or Installer can program the Auto Arm Time using this method.
[
ENTER
]
+ (Installer, Master or User code 1) +
[9]
+ 2 digits representing hours + 2 digits representing m
[
ENTER
]
8.1.2
Auto Arming Options
Feature Select Programming
D
Address 090; Key
[2]
Default: Regular Arming
The Auto Arm feature will arm the system as described in Table 11.
[
ENTER
]
+ Installer code +
[0] [9] [0]
+
[2]
ON/OFF+
[
ENTER
]
8.2
No Movement Auto Arming
Feature Select Programming
D
Address 086; Key
[6]
Default: Disabled
If the control panel does not detect any movement (zone openings) for a specified period, the panel will arm the system and
transmit the event code programmed at address 517. Please note that the type of arming is dependent on the Auto Arming
Options (see section 8.1.2). Program the No Movement Auto Arm Time as described below.
Key
[6]
OFF: No Movement Auto Arm Disabled
Key
[6]
ON: No Movement Auto Arm Enabled
[
ENTER
]
+ Installer code +
[0] [8] [6]
+
[6]
ON/OFF +
[
ENTER
]
8.2.1
No Movement Auto Arm Time
Decimal Programming
D
Address 055
Default: Disabled
000 = disabled; (001 to 255) x 15 minutes
If the No Movement Auto Arming feature (see page 32) is disabled and a time is programmed, the control panel will
transmit the event code programmed at address 517 if no movement is detected during the programmed period.
[
ENTER
]
+ Installer code +
[0] [5] [5]
+ 3-digit decimal value (001 to 255) +
[
ENTER
]
8.3
One-Key Regular Arming
Feature Select Programming
D
Address 088; Key
[7]
Default: Disabled
A user can Regular arm the system by pressing and holding the
[0]
or
[
ARM
]
key for 2 seconds.
Key
[7]
OFF: One Key Regular Arming Disabled
Key
[7]
ON: One Key Regular Arming Enabled
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[7]
ON/OFF +
[
ENTER
]
Table 11: Auto Arming Options
Key [2]
Partitioning
Options
OFF
OFF
Regular Arming
OFF
ON
Systems A and B Arming
ON
OFF
Stay Arming
ON
ON
System A Arming
Summary of Contents for ESPRIT 728 ULT
Page 1: ...Versions 4 4 728ULT 4 1 738ULT Reference Installation Manual 728ULT 738ULT ...
Page 2: ......
Page 54: ...Notes ...
Page 55: ......