U
= Default setting
Only Event Groups 000 to 055, 062 and 063 can be used to program the module’s PGM.
Warranty
For complete warranty information on this product please refer to the Limited Warranty Statement found on the website www.paradox.com/terms. Your use of the Paradox product signifies your acceptance of all
warranty terms and conditions.
We strongly advise that you review and take into consideration the “Limitations of Alarm Systems” document available on our website at
http://paradox.com/Terms/
.
© 2003-2007 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259,
5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply.
Digiplex EVO is a trademark or registered trademark of Paradox Security Systems Ltd. or its affiliates in Canada, the United States and/or other countries.
Technical Support
For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST.
Please feel free to visit our website at www.paradox.com.
SECTION [001]: Partition Assignment
SECTION [002]: General Options 1
Option
OFF
ON
Option
OFF
ON
[1]
Partition 1
N
Disabled
U
Enabled
[1]
Tamper Input
U
Disabled
N
Enabled
[2]
Partition 2
N
Disabled
U
Enabled
[2]
Battery Charging Current
U
350mA
N
850mA
[3]
Partition 3
N
Disabled
U
Enabled
[3]
Reader’s red LED to follow partition’s
status
N
Disabled
U
Enabled
[4]
Partition 4
N
Disabled
U
Enabled
[4]
Reader’s beeping to follow partition’s
status when option [3] is ON
N
Disabled
U
Enabled
[5]
Partition 5
N
Disabled
U
Enabled
[5]
Card activates door unlocked schedule
N
Disabled
U
Enabled
[6]
Partition 6
N
Disabled
U
Enabled
[6]
Door will relock
U
Imme-
diately
N
When
closed
[7]
Partition 7
N
Disabled
U
Enabled
[7]
Reader’s green LED for Access
Granted
N
Disabled
U
Enabled
[8]
Partition 8
N
Disabled
U
Enabled
[8]
Unlock on Request for Exit (REX)
N
Disabled
U
Enabled
SECTION [003]: General Options 2
SECTION [004]: PGM Options
Option
OFF
ON
Option
OFF
ON
[1]
Door Left Open Alarm
U
Disabled
N
Enabled
[1]
PGM Deactivation After
U
Deactiva-
tion Event
N
PGM Timer
[2]
Door Left Open Pre-alarm
N
Disabled
U
Enabled
[2]
PGM Normal State
U
N.O.
N
N.C.
[3]
Door Left Open Alarm
N
Silent
U
Audible
[3]
PGM Base Time
U
1 second
N
1 minute
[4]
Door Left Open Alarm follows
U
Alarm
Restore
N
Beep
Timer
[4] & [5] Special
[4]
[5]
[5]
Door Forced Open Alarm
U
Disabled
N
Enabled
N
Card Only
N
PIN Only
N
Card and PIN
U
Card or PIN
OFF
ON
OFF
ON
OFF
OFF
ON
ON
[6]
Door Forced Alarm
N
Silent
U
Audible
[7]
Door Forced Alarm follows
U
Alarm
Restore
N
Beep
Timer
[8]
Reader Access Feedback
N
Visual
U
Visual &
audible
[6]
Reader Locate Feedback
U
Visual
N
Visual &
audible
[7]
Unlock Door on Fire Alarm
U
Disabled
N
Enabled
[8]
AC and Battery Supervision
U
Enabled
N
Disabled
Section
Data
Description
Default
[005]
__/__/__ (000 to 255 x 1 minute; 000 = Instant)
AC failure report delay
030
[006]
__/__/__ (001 to 255 seconds)
Door Unlocked Period
005
[007]
__/__/__ (001 to 255 seconds added to section [006])
Door Unlocked Period extension
015
[008]
__/__/__ (001 to 255 seconds)
Door Left Open Interval
060
[009]
__/__/__ (001 to 255 seconds)
Time to start pre-alarm before alarm is triggered
Door Left Open Pre-Alarm Timer
015
[010]
__/__/__ (001 to 255 seconds)
Beep timer for Door Left Open Alarm
005
[011]
__/__/__ (001 to 255 seconds)
Beep timer for Door Forced Open alarm
005
[012]
__/__/__ (000 to 255; refer to option [3] in section [004])
PGM timer
005
[013]
Door unlock schedule
Start Time
End Time
S M T W T F S H
Schedule A:
___ ___ : ___ ___
___ ___ : ___ ___
1 2 3 4 5 6 7 8
Schedule B:
___ ___ : ___ ___
___ ___ : ___ ___
1 2 3 4 5 6 7 8
Event Group
Feature Group
Start #
End #
Section
Section
Section
Section
PGM Activation
[014]
__/__/__
[015]
__/__/__
[016]
__/__/__
[017]
__/__/__
PGM Deactivation
[018]
__/__/__
[019]
__/__/__
[020]
__/__/__
[021]
__/__/__
SECTION [022]: Safe Mode Options
SECTION [031] PGM Options 2
Option
OFF
ON
Option
OFF
ON
[1]
Safe Mode
N
Disabled
U
Enabled
[1]
Flexible PGM Deactivation Option
U
PGM
Timer only
N
Timer /
Deactivation
event
[2]
Safe Mode Access
N
Disabled
U
Enabled
[2]
Reload Timer on Activation Event
U
Don’t
Reload
N
Reload
Timer
[3]
Reader Safe Mode Feedback
U
Visual
N
Visual &
audible
[3] to [8] Future Use
N
N/A
N
N/A
[4]
Unlock Door in Safe Mode
U
Disabled
N
Enabled
[5]
Access Cards in Safe Mode
U
Safe
Cards only
N
Any Cards
[6] to [8] Future Use
N
N/A
N
N/A
Section
Data
Description
Default
[023]
__/__/__ (001 to 024 hours; 000 = Disabled)
Safe Mode Door Unlocked Period
000
[024]
__/__/__ (001 to 255 seconds; 000 = Follow REX)
REX Unlocked Period
000
[025]
__/__/__ (000 to 003)
Red LED Brightness
003
[026]
__/__/__ (000 to 003)
Green LED Brightness
003
[027]
__/__/__ (000 to 003)
Buzzer Frequency
001
[028]
__/__/__ (000 to 255 minutes; 000 = instant)
AC Restore Report Delay
005
[029]
__/__/__ (000 to 255 minutes)
Stay Lock Delay
000
[030]
Test PGM: Activates the PGM for 8 seconds to verify if the PGM is functioning properly.
[032]
__/__/__ (000 = steady, 001 to 254 = pulsed (increments of 8ms), 255 = pulsed fire)
PGM Output type
000
[040]
Access Card Serial Number Display: View an access card’s serial number displayed on any LCD or Grafica keypad on the combus.
When the DGP-ACM12 is in access card display mode, the door connected to the module cannot be accessed.
[061]
Assign Safe Mode Access Card 1 (Present Card 3 Times)
[062]
Assign Safe Mode Access Card 2 (Present Card 3 Times)
[063]
Assign Safe Mode Access Card 3 (Present Card 3 Times)
[064]
Assign Safe Mode Access Card 4 (Present Card 3 Times)
[070]
Delete All Safe Mode Access Cards
[071]
Delete Safe Mode Access Card 1
[072]
Delete Safe Mode Access Card 2
[073]
Delete Safe Mode Access Card 3
[074]
Delete Safe Mode Access Card 4