Esprit 728 Ultra & 738 Ultra
33
8.4
One-Key Stay/System A Arming
Feature Select Programming
D
Address 088; Key
[8]
Default: Disabled
Press and hold the
[
STAY
]
key for 2 seconds to Stay arm the system if partitioning is disabled. If the system is partitioned, the
control panel will arm System A.
Key
[8]
OFF: One Key Stay/System A Arming Disabled
Key
[8]
ON: One Key Stay/System A Arming Enabled
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[8]
ON/OFF +
[
ENTER
]
8.5
Arming Using a Keyswitch
Feature Select Programming
D
Address 086; Keys
[2]
and
[3]
Default: Disabled
The user can use a keyswitch to Stay arm or Regular arm/disarm the system. If the system is ready and the button is pressed, the
system will arm. Pressing the button again will disarm the system. The keyswitch will not disarm a Stay armed system in alarm.
Refer to
Keypad and Keyswitch Connections
on page 4 for installation of a keyswitch.
* If partitioning is enabled, the keyswitch will arm System A only.
[
ENTER
]
+ Installer code +
[0] [8] [6]
+
[2]
and
[3]
ON/OFF +
[
ENTER
]
8.6
Bell Squawk
Feature Select Programming
D
Address 086; Key
[
MEM
]
Default: Disabled
With this feature enabled, the bell or siren will emit a half-second squawk upon arming and two half-second squawks upon disarming.
Key
[
MEM
]
OFF: Bell Squawk Disabled
Key
[
MEM
]
ON: Bell Squawk Enabled
[
ENTER
]
+ Installer code +
[0] [8] [6]
+
[
MEM
]
ON/OFF +
[
ENTER
]
8.7
Exit Delay
Decimal Programming
D
Address 049
Default: 60 seconds
The exit delay applies to all zones. This option determines how much time the user has to leave the protected area after entering
a valid access code and before the system arms. You can program the exit delay from 001 to 255 sec.
[
ENTER
]
+ Installer code +
[0] [4] [9]
+ 3 digit decimal value (001 to 255) +
[
ENTER
]
8.8
Beep on Exit Delay
Feature Select Programming
D
Address 088; Key
[
AWAY
]/[
FORCE
]
Default: Disabled
With this feature enabled, the keypad will emit an intermittent beep during the programmed exit delay period (except when Stay
arming). The frequency of intermittent beeps increases during the last 10 seconds of the exit delay period. For more information
about the exit delay refer to section 8.7.
Key
[
AWAY
]/[
FORCE
]
OFF: Beep on Exit Delay Disabled
Key
[
AWAY
]/[
FORCE
]
ON: Beep on Exit Delay Enabled
[
ENTER
]
+ Installer code +
[0] [8] [8]
+
[
AWAY
]/[
FORCE
]
ON/OFF +
[
ENTER
]
8.9
Alarm Transmission Delay
Decimal Programming
D
Address 059
Default: Disabled
This time limit, set between 5 and 63 seconds, is the delay period before reporting an alarm to the monitoring station after an
alarm condition. During this period, disarming the system will cancel all pending alarms and send the restore codes.
Programming 000 to 004 in this address disables this feature (Maximum 30 seconds on UL listed systems).
[
ENTER
]
+ Installer code +
[0] [5] [9]
+ 3-digit decimal value (005 to 063) +
[
ENTER
]
Table 12: Keyswitch Arming Table
Key [2]
Key [3]
Function
OFF
OFF
Disabled
ON
OFF
Disabled
OFF
ON
Full Arming
ON
ON
Stay Arming
*