32
208495 REV B
Operations Manual, HPA2, Compact Outdoor SSPA
NOTE: If the Compact Outdoor unit is powered up with the Ethernet Quick
Start Cable connected to Port J4, the following default conditions apply to
the unit:
•
IPNET Interface
•
Gateway: 192.168.0.1
•
IP Address: 192.168.0.9
•
Subnet Mask: 255.255.255.0
•
Local Port: 1007
•
IP Lock: 255.255.255.255
•
Web password: paradise
•
Read Community: public
•
Write Community: private
•
Amplifier is un-muted
3.3.3 Quick Start RS-232 Connection
The following steps outline how to quickly connect to your Compact Outdoor SSPA using the
RS-232 Quick Start cable.
1. Unpack the amplifier and connect the RF Input and RF Output.
2.
Ensure the J1 RF Output port is properly terminated.
3. Connect the AC input power to connector J7.
4.
When shipped from the factory, the Compact Outdoor SSPA is set to start up
muted.
5. Connect the supplied “Quick-Start” Control Cable from Port J4 of the SSPA to one of
the COM ports on your computer. This connection will unmute the amplifier. Review
the cable schematic in
Figure 3-8
.
6. Launch the Windows-based Teledyne Paradise Datacom Universal M&C Software.
NOTE: If the Compact Outdoor unit is powered up with the RS-232 Quick
Start Cable connected to Port J4, the following default conditions apply to
the unit:
•
Normal Protocol
•
RS-232 Communication
•
Baud rate: 9600
•
Amplifier is un-muted