Installation Instructions – Kingfisher Pool Hoist 

 
Tools required: 

Hammer Drill, 16mm masonry bit, Hole Cleaning Pump, Hole Cleaning Brush, Cartridge gun 

for adhesive, Adhesive (included). 

 
Earthing

: As per AS3000 of the wiring rules standards, “In certain circumstances” it may be necessary to 

have all conductive metal objects equally potentially bonded (earthed), this includes Pool Hoists. It is 
advised to seek the opinion of a qualified electrician. 

 

1.

 

IMPORTANT: Place hoist in position, the deck should be level, if not, the hoist will need packing 
underneath the base plate, it also may need longer bolts; contact Para Mobility. Distance from the 
location point should ideally be 100mm to 500mm from the edge of pool

 Check for obstructions 

when arm of hoist is rotated. Use the hoist base as a template.  

 
NB:   Anchors must be set into the concrete NOT into the tile bed or pavers. If there are pavers 

surrounding the pool a concrete pad must be laid – contact Para Mobility for instructions. 

 
2.

 

Drill 16mm diameter hole to a minimum of 50mm into concrete substrate (i.e. 50mm 

below

 any tile 

bed). 

 
3.

 

Remove dust and debris by brushing and blowing 3 times each (If hole is wet or flooded, remove 
water with wet/dry vacuum). It is very important that the holes are

 dry and clean

 before applying 

the adhesive. 

 
4.

 

Prepare all holes and socket studs

 before continuing onto next step. 

 
5.

 

Screw mixing nozzle onto adhesive cartridge (supplied) and dispense 2-3 trigger pulls of adhesive to 
waste until colour is grey with no streaks. 

 
6.

 

Insert tip of nozzle to bottom of hole and dispense adhesive until hole is about 2/3 full. 

 
7.

 

Insert threaded stud socket, 

with M12 threaded socket on top

, with a rotating motion to release 

trapped air. Finish the top of the M12 threaded socket flush with finished floor, making sure that 
there 

is no adhesive in the threaded socket

 
8.

 

Wait until adhesive has fully cured before loading

.  

 
9.

 

Clean with acetone. 

 

 

 

Summary of Contents for KINGFISHER

Page 1: ...me pools retirement villages and hotels etc It is user operated and secured to the pool deck easily A trolley is also available which allows it to be easily moved between locations and or storage Manufactured to Australian Standard AS3581 The Kingfisher Pool Hoist has a Safe Working Load SWL of 150kg rechargeable Linak 24v battery floating hand control load bearing lift up arm rests for ease of tr...

Page 2: ...m Max Set Back 500mm Stow away size H 1230 x W 550 x D 400 Seat size 400mm x 400mm Back rest size 400mm 300mm Foot rest size 300mm x 150mm can be modified Powder coated White STANDARD INCLUSIONS Lift up arm rests 24v Battery Battery charger Battery cover Hand control Seat belt All weather cover Mounting kit OPTIONAL ACCESSORIES Foot rest Chest strap Transport trolley Phone 02 9651 4446 Delivery in...

Page 3: ...imately 1 3 of cubic metres of concrete is used when pouring your pad This can be made up as a logical size for example 1000 x 1000 x 300 or 650 x 650 x 650 The ideal location is placed up against the pool edge ANCHORING YOUR UNIT TO THE CONCRETE PAD We provide 100mm anchors as standard which have the receiver for the eye bolts This will secure the 450mm Kingfisher Pool Hoist base It s highly reco...

Page 4: ...t base Minimum concrete Thickness of 100mm Minimum concrete Thickness of 100mm Minimum concrete Thickness of 100mm Minimum concrete Thickness of 100mm 2 DO YOU HAVE THE MINIMUM CONCRETE WIDTH AND THICKNESS TO MOUNT THE HOIST ON POOL DECK YES or NO Water depth B mm Water depth Water depth Water depth D C B Customer name Pool name Contact name Ph C mm 3 Please nominate left or right hand seat B Pool...

Page 5: ...the client can transfer easily If you obtained a footrest lift the seat and remove the wing nut from tubing Place the footrest into the tubing and hand tighten the wing nut prior to use Removing the Hoist Wash the Kingfisher with clean water not chlorinated prior to packing away Remove the battery and place it on charge Bring the lifting arm up to a vertical position and fold up the seat and arms ...

Page 6: ...Lifting Arm Floating Hand Control and holder Weight bearing fold up armrests Fold up seat and footrest holder Battery Emergency stop button ...

Page 7: ...bed or pavers If there are pavers surrounding the pool a concrete pad must be laid contact Para Mobility for instructions 2 Drill 16mm diameter hole to a minimum of 50mm into concrete substrate i e 50mm below any tile bed 3 Remove dust and debris by brushing and blowing 3 times each If hole is wet or flooded remove water with wet dry vacuum It is very important that the holes are dry and clean bef...

Page 8: ...Drill hole Brush and blow Inject adhesive and insert stud NB Tiles can be core drilled 16mm for a cleaner neater finish ...

Page 9: ...o ensure it is working correctly Dropping the hand control on the ground could damage the internal workings please take care at all times Battery and Control Box Pool environments can be harsh and your battery and control box needs to be protected from the elements and chlorine products Ensure the cover remains on the control box and battery unless changing the battery Check that the battery and c...

Page 10: ... pressing a pen or similar in the hole This is a permitted method of lowering lifting The lowering lifting buttons works as normal hand control buttons you do not get extended functionality by using these when the battery is low Battery needs charging Buzzer sound is provided when a button is pressed at this battery stage Battery needs charging The battery is ok no need for charging ...

Page 11: ...y and Cover Fold up the Kingfisher Pool Hoist and put on the cover if needed Place the Kingfisher Pool Hoist on the trolley with the seat facing outwards Place the straps around the hoist to secure it in place and move as required ...

Reviews: